Fi fe – CEMB USA C75_2 (A) User Manual
Page 19
I 0461 - 19
11
FI
FE
GB
5.5.1 - Indication of exact correction weight position
It is possible use this function in the event of correction of the external side using an adhesive weight placed inside
the rim. Remember to thoroughly clean the application areas.
This function allows cancelling approximations in the mounting of counterweights with consequent reduction of the
residual unbalance.
- Press button
from the Measurements screen.
- Pull out the rim distance+diameter gauge
in position A, figure 8. Approach of the weight to the correction position
is indicated by a moving coloured arrow [
].
- When a fixed arrow [
] is reached, rotate the wheel to correction position (FI or FE) and apply the counterwei-
ght by turning the tip of the gauge towards the outside, into the position
in which the pincers touches the wheel.
Compensation is made for the fact that the weight application position is no longer at 12 o’clock (where appropriate
use the weight pusher) (fig. 11).
When the acoustic signal is enabled (see
ACOUSTIC SIGNAL
), the reaching of a fixed arrow [
] is accompanied by
a “beep”.