2 modifying set dimensions, 1 standard correction method, 2 correction method with adhesive weights (alu) – CEMB USA ER80 (D) User Manual
Page 12: 3 static & combined modes
12
1
2
3
4
5
6
Use and maintenance manual Rev. 11-2012
ENGLISH
5.1.2 Modifying set dimensions
If the wheel dimensions have been entered incorrectly,
the parameters can be modified without repeating the
balancing spin:
5.1.2.1 Standard correction method
Set the value of the dimensions in sequence:
b=width
d=diameter
a=distance
using the buttons
/
.
Press the button
to confirm the setting and go to
the next dimension.
Press the button
at any time to interrupt dimension
setting and return to the main screen.
5.1.2.2 Correction method with adhesive
weights (ALU)
Set the value of the dimensions in sequence:
aI=inside weight distance
aE=outside weight distance
dI=inside weight distance
dE=outside weight distance
using the buttons
/
.
Press the button
to confirm the setting and go
to the next dimension. Press the button
at any
time to interrupt dimension setting and return to the main
screen.
5.1.3 Static & combined modes
To change the application position of the correction weights,
press on the display near the rim section (central part of
the display):
Press near the red/orange LEDs 1-2-3-4-5.
Light alloy rim balancing with adhesive weight on the
outside (inside the rim) and adhesive or clip-on weight
on the inside:
STATIC (press twice near the LED 3 ):
Iron rim combined balancing:
To return to the main screen, press the button
. To
perform a spin, close the guard.
Use of the wheel balancer