2 measurement result, 3 static unbalance, 5 split function (unbalance resolution) – CEMB USA K11 User Manual User Manual
Page 10
10
FI
FE
1
2
1
2
Use and maintenance manual Rev. 01-2011
ENGLISH
5.2 MEASUREMENT
RESULT
Inside
correction
Outside correction
After performing a balancing spin, the amounts of unba-
lance are shown on the digital readouts. Digital readouts
with LED lit up indicate the correct angular wheel position
to mount the counterweights (12 o’clock position).
If the unbalance is less than the threshold selected,
0
is
displayed instead of the unbalance; with
it is possible
to read the values below the threshold chosen.
INDICATION
In the case of wheels with a diameter less than or equal
to 13” and at temperature conditions near 0°, the wheel
balancer automatically inserts a special measuring cycle
composed of two successive measurements. The accuracy
of the unbalance values and the reliability of the wheel
balancer remain unchanged. This type of operation is reset
each time the wheel balancer is started.
5.3 STATIC
UNBALANCE
It is selected by pressing
and is shown on the central
display. The position is indicated on the displays 3 and 4.
5.4 EXACT POSITIONING OF THE ADHESIVE
WEIGHT BY MEANS OF THE GAUGE WITH
CLIPS
P
▪
ress
if using the correction method with adhe-
sive weights on the inside of the rim
Fit the correction w
▪
eight in the specific gauge seat with
the adhesive part facing upwards
Bring the wheel into correct angular position for the
▪
plane to be corrected
Pull the gauge furthe
▪
r outwards.
Re
▪
turn the gauge to the rest position.
When the weight application distance has been reached
▪
a beep is sounded (can be deactivated).
rotate the gauge until the correction weight adheres
▪
to the rim
the fact that the weight application position is no longer
▪
vertical (see figure) is automatically compensated
INSIDE CORRECTION POSITION
▪
OUTSIDE CORRECTION POSITION
▪
INDICATION
The approach of the weights to the correction positions
is indicated by the LEDs number 18.
To cancel the function, press the
button again.
5.5
SPLIT FUNCTION
(unbalance
resolution)
The SPLIT function is used to position the adhesive weights
behind the wheel spokes (angle > 18°) so that they are
no longer visible (for alloy rims). Use this function in the
ALU or STATIC mode where the adhesive weight is ap-
plied inside the rim.
Enter the wheel dimensions in the ALU M mode and press
START.
Turn the wheel to the outer side unbalance correction
a.
position.
Mo
b.
ve one of the spokes to 12 o’clock (e.g.: 1) and
press
Use of the wheel balancer