beautypg.com

2 measurement result, 3 static unbalance, 5 split function (unbalance resolution) – CEMB USA K11 User Manual User Manual

Page 10

background image

10

FI

FE

1

2

1

2

Use and maintenance manual Rev. 01-2011

ENGLISH

5.2 MEASUREMENT

RESULT

Inside

correction

Outside correction

After performing a balancing spin, the amounts of unba-
lance are shown on the digital readouts. Digital readouts
with LED lit up indicate the correct angular wheel position
to mount the counterweights (12 o’clock position).
If the unbalance is less than the threshold selected,

0

is

displayed instead of the unbalance; with

it is possible

to read the values below the threshold chosen.

INDICATION

In the case of wheels with a diameter less than or equal
to 13” and at temperature conditions near 0°, the wheel
balancer automatically inserts a special measuring cycle
composed of two successive measurements. The accuracy
of the unbalance values and the reliability of the wheel
balancer remain unchanged. This type of operation is reset

each time the wheel balancer is started.

5.3 STATIC

UNBALANCE

It is selected by pressing

and is shown on the central

display. The position is indicated on the displays 3 and 4.

5.4 EXACT POSITIONING OF THE ADHESIVE

WEIGHT BY MEANS OF THE GAUGE WITH
CLIPS

P

ress

if using the correction method with adhe-

sive weights on the inside of the rim

Fit the correction w

eight in the specific gauge seat with

the adhesive part facing upwards
Bring the wheel into correct angular position for the

plane to be corrected
Pull the gauge furthe

r outwards.

Re

turn the gauge to the rest position.

When the weight application distance has been reached

a beep is sounded (can be deactivated).
rotate the gauge until the correction weight adheres

to the rim
the fact that the weight application position is no longer

vertical (see figure) is automatically compensated

INSIDE CORRECTION POSITION


OUTSIDE CORRECTION POSITION

INDICATION

The approach of the weights to the correction positions

is indicated by the LEDs number 18.

To cancel the function, press the

button again.

5.5

SPLIT FUNCTION

(unbalance

resolution)

The SPLIT function is used to position the adhesive weights
behind the wheel spokes (angle > 18°) so that they are
no longer visible (for alloy rims). Use this function in the
ALU or STATIC mode where the adhesive weight is ap-
plied inside the rim.

Enter the wheel dimensions in the ALU M mode and press
START.

Turn the wheel to the outer side unbalance correction

a.

position.

Mo

b.

ve one of the spokes to 12 o’clock (e.g.: 1) and

press

Use of the wheel balancer