2 self-diagnostics, 3 calibration, English – CEMB USA K9 User Manual
Page 14

14
Use and maintenance manual Rev. 04-2011
ENGLISH
6.2
SELF-DIAGNOSTICS
The machine can perform self-diagnostics to check the
LED’s on the control panel and make sure the encoder
reads correctly.
To perform this operation, view the SETUP menu.
In the self-diagnostics sequence, all the LED’s on the pa-
nel light up for a few seconds in order to check operation.
When the LED’s go out, the machine automatically moves
on to the encoder reading phase. When the wheel is turned
manually (forwards and backwards), the display shows its
exact position. The value lies between 0 (zero) and 255.
6.3
CALIBRATION
To calibrate the machine, proceed as follows:
Fit an average size wheel with a metal rim on the shaft.
▪
Example: 6” x 15” (± 1”).
Set the wheel measurements as described in paragraph
▪
USE OF THE WHEEL BALANCER.
CAUTION
S
ETTING
INCORRECT
DIMENSIONS
WOULD
MEAN
THAT
THE
MACHINE
IS
NOT
CORRECTLY
CALIBRATED
, T
HEREFORE
,
ALL
SUBSEQUENT
MEASUREMENTS
WILL
BE
INCORRECT
UNTIL
CALIBRATION
IS
PER
-
FORMED
ONCE
AGAIN
WITH
THE
CORRECT
DIMENSIONS
.
Display the SETUP menu:
P
1. ress
to view the CALIBRATION
function.
A
2. dd a standard weight of 60 g (2.00 oz) to the outer
side, in any position.
.
Sh
3.
ift the standard weight from the outside to the
inside keeping the same position.
Tu
4.
rn the wheel until the standard weight is at the top
(12
o’clock).
End of calibration.
5.
To cancel calibration at any time, press
.
6.4
AUTOMATIC GAUGES CALIBRATION
6.4.1 Rim distance gauge
Display the SETUP menu
P
1. ress
to view the rim distance
gauge CALIBRATION function.
Leave the distance gauge in rest position and press
2.
Setup
Br
3.
ing the gauge in line with the adapter flange and
press