3. Shift the standard weight from the outside to the
inside keeping the same position.
4. Turn the wheel until the standard weight is at the top
(12 o’clock).
5. End of calibration.
To cancel calibration at any time, press
.
6.5
AUTOMATIC GAUGES CALIBRATION
6.5.1 Rim distance gauge
Display the SETUP menu
1. Press
to view the rim distance
gauge CALIBRATION function.
2. Leave the distance gauge in rest position and press
3. Bring the gauge in line with the adapter flange and
press
CORRECT CALIBRATION
Return the gauge to rest position.
The wheel balancer is ready for operation.
INdIcATIoN
In the event of errors or faulty operation, the writing
“r.P.”:
ap
pears on the display : shift the gauge to the
rest position and repeat the calibration operation exactly
as described above. If the error persists, contact the
Technical Service Department. In the event of incorrect
input in the rim distance gauge calibration function, press
to cancel it.
6.5.2 Diameter gauge
E
Display the SETUP menu
1. Press
to view the diameter gauge CALI-
BRATION function.
m
Place the round part of the gauge terminal on the
flange as shown in the figure and press
2. The number 352 ± 3° appears on the left display .
3. Turn the gauge downward position the round part
of the gauge terminal at 60 mm (radial distance)
from the flange as indicated in the figure; alternati
vely use one of the cones provided as shown in the
images
4. The number 274 ± 3° should appear on the left
display. The calibration is already correct.
If not, press the
button holding the gauge still at
40 mm: the number 274 appears on the left display.
Return the gauge to rest position.
Setup