beautypg.com

2 diameter gauge – CEMB USA C212 User Manual User Manual

Page 14

background image

14

40 mm

Use and maintenance manual Rev. 10-2010

ENGLISH

3. Shift the standard weight from the outside to the

inside keeping the same position.

4. Turn the wheel until the standard weight is at the top

(12 o’clock).

5. End of calibration.

To cancel calibration at any time, press

.

6.5

AUTOMATIC GAUGES CALIBRATION

6.5.1 Rim distance gauge

Display the SETUP menu

1. Press

to view the rim distance

gauge CALIBRATION function.

2. Leave the distance gauge in rest position and press

3. Bring the gauge in line with the adapter flange and

press

CORRECT CALIBRATION
Return the gauge to rest position.
The wheel balancer is ready for operation.

INdIcATIoN

In the event of errors or faulty operation, the writing

r.P.:

ap

pears on the display : shift the gauge to the

rest position and repeat the calibration operation exactly
as described above. If the error persists, contact the
Technical Service Department. In the event of incorrect
input in the rim distance gauge calibration function, press

to cancel it.

6.5.2 Diameter gauge

E

Display the SETUP menu

1. Press

to view the diameter gauge CALI-

BRATION function.

m

Place the round part of the gauge terminal on the

flange as shown in the figure and press

2. The number 352 ± 3° appears on the left display .

3. Turn the gauge downward position the round part

of the gauge terminal at 60 mm (radial distance)

from the flange as indicated in the figure; alternati

vely use one of the cones provided as shown in the

images

4. The number 274 ± 3° should appear on the left

display. The calibration is already correct.

If not, press the

button holding the gauge still at

40 mm: the number 274 appears on the left display.
Return the gauge to rest position.

Setup