Asus DSBV-DX/C User Manual
Page 156
5-42
Chapter 5: RAID configuration
8. Repeat steps 5 and 6 to add the second disk to the volume.
9. When done, press
exit this menu.
10. The utility creates the array.
7. A confirmation screen appears.
Press
data on the first disk will be mirrored on the second disk that you will add to
the volume later. Make sure the data you want to mirror is on the first disk.
Press
Esc = Exit Menu F1/Shift+1 = Help
Space/+/- = Select disk for array or hot spare C = Create array
LSI Logic Config Utility v6.08.05.00 (2006.08.02)
Create New Array Type -- SAS1068
M - Keep existing data, migrate to an IM array.
Synchronization of disk will occur.
D - Overwrite existing data, create a new IM array.
ALL DATA on ALL disk in the array will be DELETED!!
No Synchronization performed.
Create and save new array?
Cancel Exit
Save changes then exit this menu
Discard changes then exit this menu
Exit the Configuration Utility and Reboot
LSI Logic Config Utility v6.08.05.00 (2006.08.02)
Processing...may take up 1 minute
Creating RAID array