beautypg.com

5 lsi logic mpt setup utility, 1 integrated mirroring – Asus DSBV-DX/C User Manual

Page 153

background image

ASUS DSBV-DX Series

5-39

5.5

LSI Logic MPT Setup Utility

(DSBV-DX/SAS model only)

The LSI Logic MPT Setup Utility is an integrated RAID solution that allows you to

allows you to create the following RAID set(s) from SAS hard disk drives supported

by the LSI1068 PCI-X SAS controller:

RAID 1 (Integrated Mirroring)

RAID 1E (Integrated Mirroring Enhanced)

RAID 0 (Integrated Striping)

5.5.1

Integrated Mirroring

Overview

The Integrated Mirroring (IM) feature supports simultaneous mirrored volumes with

two disks (IM). Integrated Mirroring Enhanced (IME) supports three to eight disks,

or seven mirrored disks plus a hot spare disk.
The IM feature supports hot swap capability, so when a disk in an IM volume

failes, you can easily restore the volume, and the swapped disk is automatically re-

mirrored.

Creating Integrated Mirroring volumes

• You may use disks of different sized in IM and IME volumes; however, the

size of the smallest disk determines the “logical” size of each member disk.

• DO NOT combine Serial ATA and SAS disks in one volume.
• The RAID setup screens shown in this section are for reference only and

may not exactly match the items on your screen due to the controller

version difference.

To create an IM volume:
1. Turn on the system after installing all SAS hard disk drives.
2. During POST, press to enter the SAS configuration utility.

LSI Logic Corp. MPT SAS BIOS

MPTBIOS-6.08.05.00 (2006.08.02)

Copyright 2000-2006 LSI Logic Corp.

Adapter(s) disabled by user

Press Ctrl-C to start LSI Logic Configuration Utility...

This manual is related to the following products: