3 servomotor/drive operation – PA Industries Magnum Servo Roll Feed SRF-M12/18/24/32/36/48 - Operation Manual User Manual
Page 4
![background image](/manuals/322386/4/background.png)
ULTRA MAGNUM SERVO ROLL FEED 5
/23/2003
4
ALL ULTRA MAGNUM SERVO ROLL FEED CONTROLS ARE CONVENIENTLY LOCATED
ON THE FRONT SIDE OF THE ELECTRICAL ENCLOSURE
CONTROL/DEVICE
DESCRIPTION
Power On/Reset button
Turns controller on, resets the servo drive.
In Position indicator light, white
Turns on when move is complete and motor is holding position.
Cycle Start illuminated button, green
Turns controller into “Auto” mode from “Manual” mode, starts cycling.
Cycle Stop button, red:
Stops cycling and returns the controller into “Manual” mode.
“JTL / Manual-Auto” mode selector
switch:
Turns controller into “Manual” or “JTL” (Jog To Length) mode.
Emergency Stop mushroom button, red
Shuts controller off
Operator terminal
Displays controller’s data and enters data into controller.
“Programming Locked / Unlocked” key-
switch
Locks access to programming.
Forward / Reverse and Rolls Open/Close
remote jog pendant
Pendant is attached to the enclosure through retractile cable.
2.3 SERVOMOTOR/DRIVE OPERATION
The introduction of servomotor technology to the press roll feed has pushed the limits of accuracy, adjustability,
and performance to levels previously unattainable.
The following example is based on the Ultra Magnum Servo Roll Feed Standard, US model. The actual numbers for
Heavy Duty or metric models are different.