ULTRA MAGNUM SERVO ROLL FEED 5

/23/2003

17

C r e a t e # 1



T o o l C r e a t e d

Position cursor next to desired parameter, enter appropriate value, and press the “ENTER” key.

T o o l # 1
L e n g t h 1 . 0 0 0
C o u n t C o n t . R u n
P r e s s T O O L S f o r n e x t

Press “TOOLS” key to open next screen. Position cursor next to desired parameter, enter appropriate value, and press
the “ENTER” key.

T o o l # 1
S p e e d 4 0
D w e l l 0
T O O L S - n e x t B K S P - P r e v

Press “TOOLS” key to open next screen. Position cursor next to desired parameter, enter the appropriate value, and
press the “ENTER” key. Enter “0” for Decel to use Accel value or an actual desired value.

T o o l # 1
A c c e l 4 0 0 . 0
D e c e l 4 0 0 . 0
T O O L S - n e x t B K S P - P r e v

NOTE: The following six screens are part of the optional PLS package and displayed only if the corresponding
software is loaded.

Press “TOOLS” to open the next screen. Position cursor next to desired parameter, enter new value, and then press
ENTER” key.

T o o l # 1 P o s : 3 5 4
F e e d C a m O n 2 6 0
F e e d C a m O f f 9 0
T O O L S - n e x t B K S P - P r e v

Press “TOOLS” to open the next screen. Position cursor next to desired parameter, enter new value, and press
ENTER” key.

T o o l # 1 P o s : 3 5 4
R e s e t C a m O n 1 8 0
R e s e t C a m O f f 2 0 0
T O O L S - n e x t B K S P - P r e v