10 how to synchronize press and pls, 11 how to set cam “on”/“off” parameter – PA Industries Magnum Servo Roll Feed SRF-M12/18/24/32/36/48 - Operation Manual User Manual
Page 27
ULTRA MAGNUM SERVO ROLL FEED 5
/23/2003
27
L e n g t h 1 . 0 0 0
U s e A r r o w K e y s t o
A d j u s t L e n g t h
P r e s s O P E R t o e x i t
Adjust Length using “
↑” and “↓” keys and then press “OPER” to exit adjusting.
4.10 HOW TO SYNCHRONIZE PRESS AND PLS
Open SetUp screens, find Press offset parameter, and verify its value is set to “0” and if it is not, set it so. Recycle the
power
.
P L S C o u n t s / R e v 1 0 2 4
P r e s s O f f s e t 0
S E T U P - E x i t B K S P - P r e v
Jog the press to its “0” degree (TDC) position, open status screen and read PLS position.
T o o l # P o s : 3 2 4
M a n u a l M o d e
3 0 / C o n t . R u n
P r e s s a M o d e K e y
Go back to Press offset parameter and change it to match PLS reading.
P L S C o u n t s / R e v 1 0 2 4
P r e s s O f f s e t 3 2 4
S E T U P - E x i t B K S P - P r e v
Recycle the power. Read PLS position from the status screen, it should be the same as the press’, “0” degrees.
T o o l # P o s : 0
M a n u a l M o d e
3 0 / C o n t . R u n
P r e s s a M o d e K e y
At this point the press and PLS are synchronized and you can start setting cam On/Off parameters.
4.11 HOW TO SET CAM “ON”/“OFF” PARAMETER
Open the screen that displays desired cam settings, jog the press to position where cam should turn on, read the exact
value of the press current position and enter this value for Cam On parameter.
T o o l # 1 P o s : 3 5 4
F e e d C a m O n 2 6 0
F e e d C a m O f f 9 0
T O O L S - n e x t B K S P - P r e v
Follow the same procedure to set Cam Off parameter.