Speed is the maximum velocity of the material in in/sec (or mm/sec). It is a numeric entry with a range of 0 to 72
in/sec (1828 mm/sec) for Standard model and 0 to 41 in/sec (1041 mm/sec) for Heavy Duty models.
Accel is the rate of acceleration in in/sec
2
(or mm/sec
2
). It is a numeric entry with a range of 0-to 1000 in/sec
2
(25400
mm/sec
2
). Normally set to 400 in/sec
2
(10160 mm/sec
2
).
Decel is the rate of deceleration in in/sec
2
(or mm/sec
2
). It is a numeric entry with a range of 0-to 1000 in/sec
2
(25400
mm/sec
2
). Normally set to 400-in/ sec
2
(10160 mm/sec
2
). Enter “0” to duplicate Accel rate.
D w e l l 5 0
P r e s s O P E R f o r n e x t
Dwell controls the “On” duration of the “Permit Press” output while the control is in Single Stroke mode. The next
feed length will not be started until Dwell time is expired. It is a numeric entry with a range of 0 to 100000 msec.
2.2 “SETUP” KEY
“SETUP” key controls the appearance of setup screens. Six screens contain parameters of the feed that are not
changed often or are never changed. Press “SETUP” key three times to open the first screen. Position the cursor on
the desired line, using “
↑” and “↓” keys , enter in desired value and press the “ENTER” key. Press “SETUP” key to
open the next screen or “ BKSP” – the previous.
J o g S p e e d % 5
J o g A c c e l 1 0 . 0
J o g D e c e l 1 0 . 0
S E T U P - N e x t B K S P - P r e v
Jog speed is the maximum jogging speed. It is a numeric entry with a range of 0 to 99 percent of the Speed
parameter. Normally set between 1-5%.
JogAccel is the rate of jogging acceleration. It is a numeric entry with a range of 0-to 300-in/sec
2
. Normally set 10
in/sec
2
.
JogDecel is the rate of jogging deceleration. It is a numeric entry with a range of 0-to 300-in/sec
2
. Normally set 10-
in/sec
2
.
I n P o s i t i o n 0 . 0 2 0 0
P r i o r i t y ( 1 / 0 ) F B P
A d j u s t m e n t S t e p 0 . 0 0 1
S E T U P - N e x t B K S P - P r e v
InPosition is a tolerance window around the final position. This is used to verify the feed index accuracy is within
acceptable limits before continuing onto the next function. It is a numeric entry with a range of 0 to 100 inch.
Normally set 0.02 inch.
Priority is a parameter that selects whether the feeder indexes before the press starts “FBP” or the press starts before
the feeder indexes “PBF”. Entering a “0” selects “PBF” mode and a “1” selects “FBP” mode.
AdjustmentStep is an increment of the Length adjustment. It is a numeric entry with a range of 0 to 1 inch.
Normally set 0.001 inch.