Appendix e – can messages, 50hz messages, Motec mdc 19 appendices – MoTeC MDC User Manual
Page 21

MoTeC MDC
19
Appendices
Appendix E – CAN Messages
The MDC communicates on a User CAN bus running at 1Mbit/s.
MDC operational data messages are each transmitted at 50Hz.
MDC diagnostic messages are each transmitted at 25Hz.
50Hz Messages
CAN ID 0x1F4
Byte
Bits
Data
4..7
Compound Id = 0
0
0..4
1
MDC Mode
0 = Diff open
1 to 4 = MDC user modes
5 = Constant diff lock
2
Foot brake Status (0 = Off, 1 = On)
3
Hand brake Status (0 = Off, 1 = On)
4
5
Throttle Position (0.1% resolution)
6
7
Ground Speed (0.1 km/h resolution)
CAN ID 0x1F4
Byte
Bits
Data
4..7
Compound Id = 1
0
0..4
1
Percentage Diff Lock (0.5% resolution)
2
3
Longitudinal G (0.001G resolution)
4
5
Lateral G (0.001G resolution)
6
7
Reserved
CAN ID 0x1F4
Byte
Bits
Data
4..7
Compound Id = 2
0
0..4
1
Slip Control Percentage Diff Lock (0.5% resolution)
2
Diff Current Average (0.01A resolution)
3
Diff Current Minimum (0.01A resolution)
4
Diff Current Maximum (0.01A resolution)
5
Diff+ Voltage (0.1V resolution)
6
7
ECU Efficiency Point received from ECU (0.1% resolution)
CAN ID 0x1F4
Byte
Bits
Data
4..7
Compound Id = 3
0
0..4
1
Desired slip (0.1 km/h resolution)
2
3
Hydraulic Pressure (0.1kPa resolution)
4
Mode switch status (0 = Not Active, 1 = Active)
5
Reserved
6
7
Steering Angle (1deg Resolution)