22 operation, Configure m84 ecu communications for ltc – MoTeC LTCN User Manual
Page 22

22
Operation
o
Enter 1 - PLM Receive for CAN 6 Data
o
Enter the LTC CAN address in decimal* for CAN 6 address.
The address must match the CAN address specified in LTC
Manager for the CAN Collect Master LTC. The recommended
address is 1120.
* Important: CAN addresses in ECU Manager are in decimal, while the CAN
addresses in LTC Manager are in hex. e.g. 1120 decimal = 460 hex
Configure M84 ECU Communications for LTC
•
Select Adjust > General Setup > Communication > CAN Setup
•
For single or dual LTC configuration:
o
Enter a CAN Address of 1120 (460 Hex) into the PLM CAN
Address
Assign Lambda measurements to a Hundred Series channel
Lambda measurements from the LTCs must be assigned to an ECU channel
before they can be used for engine control or logging.
•
Select Adjust > Sensor Setup > Input Setup... to open the Input Pins Setup
dialog.
•
Attach an LTC reading to a channel, using the following parameters
Input Source
Predefined Calibration
PLM 1 to PLM 12
#81 Lambda: PLM over CAN
Example 1: LTC1 reading assigned to channel Lambda 1