Motec configuration 11, Ltc-n output table – MoTeC LTCN User Manual
Page 11

MoTeC
Configuration
11
Note: Lambda sensors should not be left in the exhaust system of a
running engine if they are not being controlled. A disabled sensor in a
running engine can be damaged.
•
In the Name area the default name will appear. The default name matches
the selected CAN Address (LTC1 etc.). If required the user can specify a
custom name (e.g. Left Bank or Cylinder 4).
Tip: The rows in the main LTC Manager window are sorted by the Name
column.
•
Select a Standard Sensor type from the drop down menu
OR
Select a Custom Sensor
Note: Custom sensor setups are for advanced users and it is not
recommended for general use.
•
Select a Standard Output Table, generally Lambda to three decimal
places
OR
Use a Custom Table for another type of fuel, e.g. Diesel.
• Click OK. The configuration updates will be sent to the LTC, this may take
several seconds
LTC-N Output Table
The standard output table for the LTC-N is for Lambda to three decimal places.
It is possible for the user to make a custom table to suit the Air/Fuel ratio of any
fuel.