Configuration

• Click OK. The configuration updates will be sent to the LTC, this may take

several seconds

LTC-N Unit Setup

To open the LTC Setup window, double click the row in the table
containing the LTC or click the row and click Setup.

Select the Recommended Address check box and enter one of the
addresses in the drop down box to communicate with MoTeC products
such as Data Loggers or 'hundred series' ECUs.
The recommended address range for LTC messages is hex 460 to hex
47F.

OR

Select the Custom Address check box and enter an address (in hex) for
interfacing with third party equipment.

OR

Select Disabled to prevent an LTC from transmitting CAN messages.
While disabled an LTC will not heat the sensor or perform Lambda
measurements.