Vimcom" errors, C185 errors, 68 appendices motec – MoTeC C185 User Manual
Page 73
68
Appendices
MoTeC
8
OVERRUN
Receive or transmit overrun error. In the
receive case a byte was received before the
previous byte was read indicating that the
processor is too busy to read the message.
In the transmit case the transmit buffer is full
which could happen if the CAN bus is too
busy.
256
BAD CONFIG
The device configuration is not valid (eg
overlapping CAN addresses)
512
NO DATA
A valid message header was not found -
either there is a wiring fault or comms is
setup incorrectly, (problem could be at either
end). E.g.: transmit and receive CAN IDs do
not match.
1024
CHECKSUM
Only generated when used with an Async
Expander. See RS232 errors
2048
WRONG DATA
Only generated when used with an Async
Expander or E888/E816 Expander. Async
Expander: Could not decode the protocol.
E888/E816: Compound ID incorrect.
4096
BUS WARNING
More than 96 errors have occurred on the
CAN bus. Check wiring and termination
resistors. The CAN bus may still be
operational.
8192
BUS OFF
More than 255 errors have occurred on the
CAN bus. CAN communications is
suspended when this error occurs. Check
wiring, termination resistors and the CAN
baud rate. Also check that CAN HI and CAN
LO are correct (not swapped).
16384
CAN TRANSMIT
CAN bus transmit warning
"VIMCOM" Errors
Errors generated by "VIMCOM" devices (VIM, ADL2, SDL).
Note: VIM COM devices are connected via CAN.
C185 Errors
These errors are generated by the C185 communications system.
2
FRAMING
Incorrect number of samples received.