MoTeC

Appendices

67

Comms Error Codes

The "Comms CAN x Diagnostic" and "Comms RS232 Diagnostic" channels
seen can be used to diagnose communications problems.

Multiple errors are shown by error codes added together. For example: A
RS232 error of 9 = parity + overrun.

The error values have the following definitions:

RS232 Errors

Errors generated by RS232 communications.

1

PARITY

Parity bit incorrect. The comms parity setup is
wrong, or there is electrical interference
causing errors in the data.

2

FRAMING

Not seeing the stop bit. The baud rate or stop
bit setup is wrong or there is electrical
interference causing errors in the data.

4

NOISE

Glitch in the data. Electrical interference is
causing glitches in the signal. (C185 does not
generate this error)

8

OVERRUN

A byte was received before the previous byte
was read indicating that the processor was too
busy to read the message.

512

NO DATA

A valid message header was not found - either
there is a wiring fault or comms is setup
incorrectly.

1024

CHECKSUM

A valid message header was found, but the
checksum was wrong. If seen in combination
with other errors there is electrical noise. If only
checksum errors occur there may be a
software incompatibility between the C185 and
the other device.

2048

WRONG DATA

Could not decode the protocol.

General CAN Errors

Errors generated by general CAN communications.

2

FRAMING

Only generated when used with an
E888/E816 expander. Inconsistent message
length.