SPECIFICATIONS:

Rated 0-5 gpm (0-19 lpm).

Rated for 6000 psi (414 bar).

Weighs 1.25 lbs. (0.6 kg).

Standard port size 1/4” NPT all.

30 in lbs (3.4 Nm) to turn HPV4 spool @ 3000
psi (207 bar).

15 degrees of rotation before work ports open to
pressure or tank.

30 – Micron filtration recommended.

MOUNTING INSTRUCTIONS:


Mounting – Valve can be mounted in any orientation. Valve must be mounted on a flat surface. Special attention should
be paid to not bend or twist the casting when mounting. Doing so may cause the valve to fail.

FREQUENTLY ASKED QUESTIONS:

Q: How many in-lb is required to turn HPV4 spool at 3000psi?
A: 30 in-lb is required.

Q: How many degrees of rotation are required from neutral before work ports open to tank?
A: 15 degrees is required.

Q: What kits are available for this valve?
A: There is a replacement seal kit (Part #: HPV4-K)

Q: Can I paint the valve?
A: Painting valves is acceptable as long as all ports are plugged.

GENERAL INFORMATION:


Pipe Thread Sealant - Warranty is void when Teflon tape is used to seal pipe threads. This is because Teflon tape is a
friction reducing agent which allows customers to over-torque fittings. We recommend using a sealant that does not include
friction reducing agents i.e. Lead Plate.

DIMENSIONAL DATA:

PO RT B
(TANK)

INLET
(B)

PO RT A
(INLET)

TANK
(A)

1
4

" N PT

ALL PO RTS

1/4-20 U NC

(2 PLACES)

0.25"

1.28"

0.98"

2.49"

3.94"

1.80"

(HP V4-T4)

H P V4 SH O W N