P/N VDC12248/24041-MNL

Specific Gravity – Capacity

Temperature Compensated

Hydrometer - Meter or 4 ball type

Full Capacity

Percentage

1.270 (4 Balls floating)

100%

1.250 (3 Balls floating)

75%

1.190 (2 Balls floating)

50%

1.150 (1 Balls floating)

25%

1.120 (0 Balls floating)

May denote shorted cell or battery that has

been severely discharged and may not be

recoverable

0%

and completely charged before you determine its condition. Allow battery
to “rest” (see

Glossary of Terms) overnight for a minimum of 12 hours

before testing with a temperature compensated hydrometer and/or digital
type voltmeter only.