BatteryMINDer 24041 User Manual
Page 8
BatteryMINDer
®
Models 12248 & 24041
Rev. C-082713
Page 8
P/N VDC12248/24041-MNL
Specific Gravity – Capacity
Temperature Compensated
Hydrometer - Meter or 4 ball type
Full Capacity
Percentage
1.270 (4 Balls floating)
100%
1.250 (3 Balls floating)
75%
1.190 (2 Balls floating)
50%
1.150 (1 Balls floating)
25%
1.120 (0 Balls floating)
May denote shorted cell or battery that has
been severely discharged and may not be
recoverable
0%
and completely charged before you determine its condition. Allow battery
to “rest” (see
Glossary of Terms) overnight for a minimum of 12 hours
before testing with a temperature compensated hydrometer and/or digital
type voltmeter only.
This manual is related to the following products: