BatteryMINDer 24041 User Manual
Page 19

BatteryMINDer
®
Models 12248 & 24041
Rev. C-082713
Page 19
P/N VDC12248/24041-MNL
The chart below shows the need to regulate the output voltage of the charger
to ensure against over or under charging your battery over a wide range of
temperatures.
Temperature Compensated Flooded Battery*
Charge and Float Voltages
12V
24V
Temperature
Charge
Float
Charge
Float
> 120°F
13.8
12.8
27.6 V
25.6 V
110°F - 120°F
13.9
12.9
27.8 V
25.8 V
100°F - 110°F
14.0
13.0
28.0 V
26.0 V
90°F - 100°F
14.1
13.1
28.2 V
26.2 V
80°F - 90°F
14.3
13.3
28.6 V
26.6 V
70°F - 80°F
14.4
13.4
28.8 V
26.8 V
60°F - 70°F
14.6
13.6
29.2 V
27.2 V
50°F - 60°F
14.8
13.8
29.6 V
27.6 V
40°F - 50°F
15.0
14.0
30.0 V
28.0 V
< 40°F
15.1
14.1
30.2 V
28.2 V
*AGM Charge & Float: +0.6 V (
12248
) / +0.8 V (
24041
)
Gel Charge & Float: -0.6 V (
12248
) / -0.8 V (
24041
)