Page 27

BatteryMINDer
©
Model 12248-A-ODY
Rev. D-050509
Page 2
P/N VDC12248-A-ODY-MNL
DETAILED SPECIFICATIONS -
VDC Model No. 12248-A-ODY (con’t.)
Transformer
Transformer Type: Ferrite core transformer
Rising Temperature of Transformer: 80º C Max.
Insulation
Primary to Secondary insulation Test:
1240 Vac 60Hz with
1 minutes, 10mA ac no break down found
Primary to core insulation test:
1240 Vac 60Hz with 1 min-
utes, 10mA ac no break down found
Secondary to core insulation test: 500 Vac 60Hz with 1 min-
utes, 10mA ac no break down found
Electrical Cable
Input Lead and plug specifications :CUL SJT 18AWG X2 with
UL 2-pin plug, External Length 6 ft
Output lead : 1015 105° C VW-1 16AWG with Trailer connec-
tor, External Length 2 ft
Extension cord: 1)1015 105° C VW-1 16AWG with Trailer con-
nector & battery clamp, External Length 2 ft
2)1015 105° C VW-1 16AWG with Ring terminal &
blade type Fuse, External Length 2 ft
Ring terminal I.D dimensions
Negative 8mm, Positive
10mm
Physical Parameters
Weight: 2.2 lbs.
Plastic enclosure material: UL-94V0 #1 Noryl or #2 PC+ABS
#3 PC
Enclosure Dimension:
Approx. 5.713 (W) x 5.516 (L) x
2.86 (H) inches
Environmental Characteristics
Operating temperature : -10° to 40° C
Storage temperature : -10° to 80° C
Operating Humidity range: 0 to 95% RH