beautypg.com

BatteryMINDer 12248-A-ODY User Manual

Page 24

background image

BatteryMINDer

©

Model 12248-A-ODY

Rev. D-050509

Page 24

P/N VDC12248-A-ODY-MNL

DETAILED SPECIFICATIONS -

VDC Model No. 12248-A-ODY (con’t.)

Charging Output Control Characteristics
Charging Flow: Battery condition detect>SoftStart
Charge>Bulk Charge

Absorption Charge>Sulphate Check>Float Charge>Float

Pulse Charge
SoftStart Charging Activity conditions:

1) Battery Voltage is over 3 Vdc and less than 10.5 Vdc

2) Press Start Button (If you forget to press Start button

within 10 minutes, charger will automatically start in and re-
main in 2A current mode & Gel Battery mode)
Soft Start Charging output current control:
(8A Charging Rate) 2.0 Adc ±0.25
Soft Start Charging Time Limit: 6 Hours
Bulk Charging Activity conditions:

1) Battery Voltage is over 10.5 Vdc

Bulk Charging Current control at 8A mode: 8 Adc ±0.45

Max. rated output voltage and current: 13.5V at 8Adc --
14.7V at 6.5Adc
Bulk Charging Time Limit: 20 ±1 Hours
Absorption Charge mode Output voltage control
14.7 (AGM-ODYSSEY) @ 24°C ±0.25 VDC