beautypg.com

Specifications, Dc voltage, Ac voltage – B&K Precision 5491B - Datasheet User Manual

Page 3: Dc current

background image

2

8

3

1

E

5

4

9

1

B

3

w w w.bk prec ision.c om

True RMS Bench Multimeters

Models 2831E and 5491B

Resolution, Full Scale Reading and Accuracy ± (% of reading + % of range), 23 °C ± 5 °C

Rate

Range

Re solution

Fu ll Scale

Re ading

Accu racy

(1 year)

T ypical I nput

I mpedance

Slow

200.00 mV

10 µV

210.00

0.03%+0.08% (1)

>10 MΩ

2.0000 V

100 µV

2.1000

0.03%+0.05% (1)

>11.1 MΩ

20.000 V

1 mV

21.000

0.03%+0.06%

>10.1 MΩ

200.00 V

10 mV

210.00

0.03%+0.06%

10 MΩ

1000.0 V

100 mV

1010.0 (2)

0.03%+0.06%

10 MΩ

Slow

500.00 mV

10 µV

510.00

0.02%+0.016% (1)

>10 MΩ

5.0000 V

100 µV

5.1000

0.02%+0.008% (1)

>11.1 MΩ

50.000 V

1 mV

51.000

0.02%+0.008%

>10.1 MΩ

500.00 V

10 mV

510.00

0.02%+0.008%

10 MΩ

1000.0 V

100 mV

1010.0 (2)

0.02%+0.008%

10 MΩ

(1) under REL status

(2) 1% over-range (1010 V) is readable at 1000 V range

DC Voltage

Resolution, Full Scale Reading and Accuracy ± (% of reading + % of range), 23 °C ± 5 °C

Rate

Range

Re solution

Full Scale

Readi ng

Accuracy(1 ye ar)(1) 23 ° C ± 5 ° C

20~50 Hz

50~20 kH z

20~50 kHz

50~100 kHz

S low

200.00 mV

10 µV

210.00

1.0%+0.2%)

0.5%+0.15%

1.8% + 0.25%

3.0% + 0.75%

2.0000 V

100 µV

2.1000

1.0%+0.2%)

0.4%+0.05%

1.5% + 0.1%

3.0% + 0.25%

20.000 V

1 mV

21.000

1.0%+0.2%

0.4%+0.05%

1.5% + 0.1%

3.0% + 0.25%

200.00 V

10 mV

210.00

----

0.8%+0.075%

1.5% + 0.1%

3.0% + 0.25%

750.0 V

100 mV

757.5(3)

----

0.8%+0.075%

1.5% + 0.1% (2)

3.0% + 0.25% (2)

S low

500.00 mV

10 µV

510.00

1.0%+0.08%)

0.5%+0.06%

1.5% + 0.1%

3.0% + 0.3%

5.0000 V

100 µV

5.1000

1.0%+0.08%)

0.35%+0.02%

1% + 0.04%

3.0% + 0.1%

50.000 V

1 mV

51.000

1.0%+0.08%

0.35%+0.02%

1% + 0.04%

3.0% + 0.1%

500.00 V

10 mV

510.00

----

0.5%+0.03%

1% + 0.04%

3.0% + 0.1%

750.0 V

100 mV

757.5(3)

----

0.5%+0.03%

1% + 0.04% (2)

3.0% + 0.1% (2)

Max. crest factor: 3.0 at full scale

(1) Specifications are for sine wave inputs >5% of range.

(2) Limit at 40 kHz or 3×107 Volt-Hz for 750 V range

(3) 1% over-range (757.50V) is readable at 750V range

AC Voltage

Specifications

2

8

3

1

E

5

4

9

1

B

2

8

3

1

E

5

4

9

1

B

Resolution, Full Scale Reading and Accuracy ± (% of reading + % of range), 23 °C ± 5 °C

Rate

Range

Resolu tion

Fu ll Scale

Re ading

Accuracy

(1 ye ar)

B urden Voltage (1)

& Shu nt Re sistor

S low

2.0000 mA

0.1 µA

2.1000

0.08%+0.025% (2)

<0.3 V / 100 Ω

20.000 mA

1 µA

21.000

0.08%+0.02% (2)

<0.04 V / 1 Ω

200.00 mA

10 µA

210.00

0.08%+0.02%

<0.3 V / 1 Ω

2.0000 A

100 µA

2.1000

0.3%+0.025%

<0.05 V / 10 mΩ

20.000 A

1 mA

21.000 (3)

0.3%+0.025%

<0.6 V / 10 mΩ

S low

5.0000 mA

0.1 µA

5.1000

0.05%+0.01% (2)

<0.6 V / 100 Ω

50.000 mA

1 µA

51.000

0.05%+0.008% (2)

<0.06 V / 1 Ω

500.00 mA

10 µA

510.00

0.05%+0.008%

<0.6 V / 1 Ω

5.0000 A

100 µA

5.1000

0.25%+0.01%

<0.1 V / 10 mΩ

20.000 A

1 mA

21.000 (3)

0.25%+0.01%

<0.6 V / 10 mΩ

(1) Typical voltage across the input terminals at full scale reading.

(2) Use REL function

(3) In 20 A range, >10~20 ADC is readable for 20 seconds maximum

DC Current