AUTO MODE

RS-170A HORIZONTAL BLANKING INTERVAL TIMING MEASUREMENTS

Measurement

Range

Accuracy

Test Signal

Color Burst Width

6 to 13 cycles

±0.1 cycles

Horizontal Blanking

Front Porch Duration

0.5 to 2 µs

±20 ns

Horizontal Blanking

Horizontal Blanking Width

6 to 30 µs

±50 ns

Horizontal Blanking

Horizontal Sync Rise

80 to 120 ns

–10 to +30 ns

Horizontal Blanking

Time and Fall Time

120 to 300 ns

±20 ns

300 ns to 1.0 µs

±30 ns

Horizontal Sync Width

1 to 8 µs

±10 ns

Horizontal Blanking

SCH Phase

±90 deg

±5 deg

Horizontal Blanking

Sync to Setup

5 to 18 µs

±20 ns

Horizontal Blanking

Sync to Start of Burst

4 to 8 µs

±140 ns

Horizontal Blanking

(0.5 cycles)
±20 ns

RS-170A VERTICAL BLANKING INTERVAL

Measurement

Range

Accuracy

Test Signal

Equalizing Pulse Width

1 to 20 µs

±10 ns

Vertical Blanking

Serration Width

1 to 20 µs

±10 ns

Vertical Blanking

Vertical Blanking Width

19 to 29 lines

–0.1 lines to

Vertical Blanking

+0.2 lines

FCC HORIZONTAL BLANKING INTERVAL TIMING MEASUREMENTS

Measurement

Range

Accuracy

Test Signal

Breezeway Width

0.2 to 3.5 µs

±25 ns

Horizontal Blanking

Color Burst Width

6 to 13 cycles

±0.1 cycles

Horizontal Blanking

Front Porch Duration

0.5 to 2 µs

±10 ns

Horizontal Blanking

Horizontal Blanking Width

6 to 30 µs

±10 ns

Horizontal Blanking

Horizontal Sync Rise Time

80 to 120 ns

–10 to +30 ns

Horizontal Blanking

and Fall Time

120 to 300 ns

±20 ns

300 ns to 1.0 µs

±30 ns

Horizontal Sync Width

1 to 8 µs

±10 ns

Horizontal Blanking

Sync to Setup

5 to 18 µs

±20 ns

Horizontal Blanking

Sync to End of Burst

6 to 15 µs

±20 ns

Horizontal Blanking

FCC VERTICAL BLANKING INTERVAL TIMING MEASUREMENTS

Measurement

Range

Accuracy

Test Signal

Equalizing Pulse Width

25 to 100%

±0.3%

Vertical Blanking

of nominal
horizontal sync
pulse width

Serration Width

1 to 20 µs

±10 ns

Vertical Blanking

Vertical Blanking Width

19 to 29 lines

–0.1 lines to

Vertical Blanking

+0.2 lines

AMPLITUDE AND PHASE MEASUREMENTS

Measurement

Range

Accuracy

Test Signal

Average Picture Level (APL)

0 to 200%

±3.0%

Full Field

Bar Top

0 to 90% of

±0.1%

FCC/NTC-7 Composite

Maximum Carrier

Bar Amplitude

0 to 200 IRE

±0.3 IRE

FCC/NTC-7 Composite

Chrominance to

±300 ns

±5 ns

FCC/NTC-7 Composite

Luminance Delay
(Relative Chroma Time)

Chrominance to

0 to 160%

±1%

FCC/NTC-7 Composite

Luminance Gain
(Relative Chroma Level)

Differential Gain

0 to 100%

±0.3%

FCC/NTC-7 Composite

AMPLITUDE AND PHASE MEASUREMENTS (continued)

Measurement

Range

Accuracy

Test Signal

Differential Phase

0 to 360 deg

±0.3 deg

FCC/NTC-7 Composite

Luminance Non-linear

0 to 50%

±0.4%

FCC/NTC-7 Composite

Distortion

Relative Burst Gain

±100%

±0.3%

FCC/NTC-7 Composite

Relative Burst Phase

±180 deg

±0.3 deg

FCC/NTC-7 Composite

Burst Amplitude

25 to 200%

±1.0%

Horizontal Blanking

(% of sync)

of sync

Burst Amplitude

10 to 80% of Bar

±0.4%

Horizontal Blanking

(% of Bar)

(10 to 80 IRE when (±0.4 IRE)
Bar is not used)

Sync Amplitude

20 to 80% of Bar

±0.3%

Horizontal Blanking

(% of Bar)

(20 to 80 IRE when (±0.3 IRE)
Bar is not used)

Blanking Level

0 to 90% of

±0.2%

Horizontal Blanking

Maximum Carrier

Sync Variation

0 to 50% of

±0.3% for

Horizontal Blanking

Maximum Carrier

Zero Carrier

(0 to 50% of Bar

(±0.3% for Bar

when Zero Carrier

and ±0.3 IRE

is not used and

for no Zero

0 to 50 IRE when

Carrier and

Zero Carrier and

no Bar)

Bar are not used)

Blanking Variation

0 to 50% of

±0.3% for

Horizontal Blanking

Maximum Carrier

Zero Carrier

(0 to 50% of Bar

(±0.3% for Bar

when Zero Carrier

and ±0.3 IRE

is not used and

for no Zero

0 to 50 IRE when

Carrier and

Zero Carrier and

no Bar)

Bar are not used)

FREQUENCY RESPONSE MEASUREMENTS

Measurement

Range

Accuracy

Test Signal

Multiburst Flag

0 to 90% of

±0.5% for

FCC Multiburst or

Amplitude

Maximum Carrier

Zero Carrier

NTC-7 Combination

(20 to 130% of

(±0.5% for Bar

Bar when Zero

and ±0.5 IRE

Carrier is not used for no Zero
and 20 to 130 IRE

Carrier and

when Zero Carrier no

Bar)

and Bar are
not used)

Multiburst Packet

0 to 100% of Flag

±1% of Flag

FCC Multiburst or

Amplitudes

NTC-7 Combination

INCIDENTAL CARRIER PHASE MODULATION

Measurement

Range

Accuracy

Test Signal

ICPM (requires Zero

0 to 30 deg

±1.0 deg

FCC or NTC-7

Carrier Pulse and the

Composite

quadrature output of the

demodulator on

channel C)

COLOR BAR MEASUREMENTS

Measurement

Range

Accuracy

Test Signal

Color Bar Amplitude Errors

±100% of nominal

±1.0%

FCC Color Bars

Color Bar Phase Errors

±180 deg from

±0.5 deg

FCC Color Bars

nominal

Color Bar Chrominance to

0 to 200% of

±2%

FCC Color Bars

Luminance Gain Ratio

nominal

9