Auto mode, Rs-170a vertical blanking interval, Fcc vertical blanking interval timing measurements – Atec Tektronix-VM700T User Manual
Page 9: Amplitude and phase measurements, Amplitude and phase measurements (continued), Frequency response measurements, Incidental carrier phase modulation, Color bar measurements
![background image](/manuals/320048/9/background.png)
AUTO MODE
RS-170A HORIZONTAL BLANKING INTERVAL TIMING MEASUREMENTS
Measurement
Range
Accuracy
Test Signal
Color Burst Width
6 to 13 cycles
±0.1 cycles
Horizontal Blanking
Front Porch Duration
0.5 to 2 µs
±20 ns
Horizontal Blanking
Horizontal Blanking Width
6 to 30 µs
±50 ns
Horizontal Blanking
Horizontal Sync Rise
80 to 120 ns
–10 to +30 ns
Horizontal Blanking
Time and Fall Time
120 to 300 ns
±20 ns
300 ns to 1.0 µs
±30 ns
Horizontal Sync Width
1 to 8 µs
±10 ns
Horizontal Blanking
SCH Phase
±90 deg
±5 deg
Horizontal Blanking
Sync to Setup
5 to 18 µs
±20 ns
Horizontal Blanking
Sync to Start of Burst
4 to 8 µs
±140 ns
Horizontal Blanking
(0.5 cycles)
±20 ns
RS-170A VERTICAL BLANKING INTERVAL
Measurement
Range
Accuracy
Test Signal
Equalizing Pulse Width
1 to 20 µs
±10 ns
Vertical Blanking
Serration Width
1 to 20 µs
±10 ns
Vertical Blanking
Vertical Blanking Width
19 to 29 lines
–0.1 lines to
Vertical Blanking
+0.2 lines
FCC HORIZONTAL BLANKING INTERVAL TIMING MEASUREMENTS
Measurement
Range
Accuracy
Test Signal
Breezeway Width
0.2 to 3.5 µs
±25 ns
Horizontal Blanking
Color Burst Width
6 to 13 cycles
±0.1 cycles
Horizontal Blanking
Front Porch Duration
0.5 to 2 µs
±10 ns
Horizontal Blanking
Horizontal Blanking Width
6 to 30 µs
±10 ns
Horizontal Blanking
Horizontal Sync Rise Time
80 to 120 ns
–10 to +30 ns
Horizontal Blanking
and Fall Time
120 to 300 ns
±20 ns
300 ns to 1.0 µs
±30 ns
Horizontal Sync Width
1 to 8 µs
±10 ns
Horizontal Blanking
Sync to Setup
5 to 18 µs
±20 ns
Horizontal Blanking
Sync to End of Burst
6 to 15 µs
±20 ns
Horizontal Blanking
FCC VERTICAL BLANKING INTERVAL TIMING MEASUREMENTS
Measurement
Range
Accuracy
Test Signal
Equalizing Pulse Width
25 to 100%
±0.3%
Vertical Blanking
of nominal
horizontal sync
pulse width
Serration Width
1 to 20 µs
±10 ns
Vertical Blanking
Vertical Blanking Width
19 to 29 lines
–0.1 lines to
Vertical Blanking
+0.2 lines
AMPLITUDE AND PHASE MEASUREMENTS
Measurement
Range
Accuracy
Test Signal
Average Picture Level (APL)
0 to 200%
±3.0%
Full Field
Bar Top
0 to 90% of
±0.1%
FCC/NTC-7 Composite
Maximum Carrier
Bar Amplitude
0 to 200 IRE
±0.3 IRE
FCC/NTC-7 Composite
Chrominance to
±300 ns
±5 ns
FCC/NTC-7 Composite
Luminance Delay
(Relative Chroma Time)
Chrominance to
0 to 160%
±1%
FCC/NTC-7 Composite
Luminance Gain
(Relative Chroma Level)
Differential Gain
0 to 100%
±0.3%
FCC/NTC-7 Composite
AMPLITUDE AND PHASE MEASUREMENTS (continued)
Measurement
Range
Accuracy
Test Signal
Differential Phase
0 to 360 deg
±0.3 deg
FCC/NTC-7 Composite
Luminance Non-linear
0 to 50%
±0.4%
FCC/NTC-7 Composite
Distortion
Relative Burst Gain
±100%
±0.3%
FCC/NTC-7 Composite
Relative Burst Phase
±180 deg
±0.3 deg
FCC/NTC-7 Composite
Burst Amplitude
25 to 200%
±1.0%
Horizontal Blanking
(% of sync)
of sync
Burst Amplitude
10 to 80% of Bar
±0.4%
Horizontal Blanking
(% of Bar)
(10 to 80 IRE when (±0.4 IRE)
Bar is not used)
Sync Amplitude
20 to 80% of Bar
±0.3%
Horizontal Blanking
(% of Bar)
(20 to 80 IRE when (±0.3 IRE)
Bar is not used)
Blanking Level
0 to 90% of
±0.2%
Horizontal Blanking
Maximum Carrier
Sync Variation
0 to 50% of
±0.3% for
Horizontal Blanking
Maximum Carrier
Zero Carrier
(0 to 50% of Bar
(±0.3% for Bar
when Zero Carrier
and ±0.3 IRE
is not used and
for no Zero
0 to 50 IRE when
Carrier and
Zero Carrier and
no Bar)
Bar are not used)
Blanking Variation
0 to 50% of
±0.3% for
Horizontal Blanking
Maximum Carrier
Zero Carrier
(0 to 50% of Bar
(±0.3% for Bar
when Zero Carrier
and ±0.3 IRE
is not used and
for no Zero
0 to 50 IRE when
Carrier and
Zero Carrier and
no Bar)
Bar are not used)
FREQUENCY RESPONSE MEASUREMENTS
Measurement
Range
Accuracy
Test Signal
Multiburst Flag
0 to 90% of
±0.5% for
FCC Multiburst or
Amplitude
Maximum Carrier
Zero Carrier
NTC-7 Combination
(20 to 130% of
(±0.5% for Bar
Bar when Zero
and ±0.5 IRE
Carrier is not used for no Zero
and 20 to 130 IRE
Carrier and
when Zero Carrier no
Bar)
and Bar are
not used)
Multiburst Packet
0 to 100% of Flag
±1% of Flag
FCC Multiburst or
Amplitudes
NTC-7 Combination
INCIDENTAL CARRIER PHASE MODULATION
Measurement
Range
Accuracy
Test Signal
ICPM (requires Zero
0 to 30 deg
±1.0 deg
FCC or NTC-7
Carrier Pulse and the
Composite
quadrature output of the
demodulator on
channel C)
COLOR BAR MEASUREMENTS
Measurement
Range
Accuracy
Test Signal
Color Bar Amplitude Errors
±100% of nominal
±1.0%
FCC Color Bars
Color Bar Phase Errors
±180 deg from
±0.5 deg
FCC Color Bars
nominal
Color Bar Chrominance to
0 to 200% of
±2%
FCC Color Bars
Luminance Gain Ratio
nominal
9