beautypg.com

Atec Tektronix-AWG610 User Manual

Page 3

background image

Arbitrary Waveform Generator

AWG610

Threshold –
Level: –5.0 V to 5.0 V.
Resolution: 0.1 V.
Accuracy: ±(5% of level + 0.1 V).
Pulse Width (0.2 V amplitude): 10 ns minimum.
Trigger Holdoff: ≥576 clocks + 450 ns.
Delay to Marker: 28 ns + 22 clocks.
Delay to Analog Out: (typical).
(filter through).
30 ns + 22 clocks (trigger).
30 ns + 880 clocks (gate).
Connector: Rear-panel BNC.

Event Trig Input –
Number of Events: 4 Bits.
Input Signals: 4 event bits, strobe.
Threshold: TTL level.
Pulse Width: 128 clocks minimum.
Maximum Input: 0 V to +5 V (DC + peak AC).
Delay to Analog Out: 850 clocks +20 ns
(ASYNC mode).
Impedance 2.2 kΩ, pull-up to +5 V.
Connector: Rear-panel 9-Pin D-sub.

Reference 10 MHz Clock IN –
Input Voltage Range: 0.2 V to 3.0 V

p-p

,

±10 V maximum.
Impedance: 50 Ω, AC coupled.
Frequency Range: 10 MHz ±0.1 MHz.
Connector: Rear-panel BNC.

General
Characteristics

Display

Area – 13.2 cm (5.2 in.) horizontal by 9.9 cm
(3.9 in.) vertical.

Resolution – 640 horizontal by 480 vertical pixels.

Data Storage

Internal Hard Disk Drive – 3.0 GB (standard).

Floppy Disk Drive – 3.5 in., 1.44 MB.

Option 10 –
Flash Disk replaces HDD, 78 MB. (Opt. 10 is best
suited for ATE and system usage requiring 7x24
hour operation.)

Environmental, EMC, Safety

Temperature –
Operating: 10 ºC to +40 ºC.
Nonoperating: –20 ºC to +60 ºC.

Humidity –
Operating: 20 to 80%, noncondensing.
Nonoperating: 5 to 90%, noncondensing.

Altitude –
Operating: Up to 4,500 m. (15,000 ft.). Maximum
operating temperature decreases 1 ºC per 300 m
above 1.5 km.
Nonoperating: Up to 15,000 m (50,000 ft.).

Vibration (Test Limits) –
Operating: 0.27 G

RMS

from 5 to 500 Hz, 10 minutes.

Nonoperating: 2.28 G

RMS

from 5 to 500 Hz,

10 minutes.

Shock (Test Limits) –
Nonoperating: 294 m/s

2

(30 G), half-sine,

11 ms duration.

EMC Compliance –
EN50081-1, EN50082-1.
AS/NZS 20641/2.

Safety – UL3111-1, CSA1010.1, EN61010-1,
IEC61010-1.

Power

Source Power –
Line Voltage Range: 100 to 240 VAC.
Line Frequency: 48 to 63 Hz.

Power Consumption – 600 W at 8 A.

P h y s i c a l
C h a r a c t e r i s t i c s
Dimensions

mm

in.

Height

193

7.6

Width

422

16.6

Depth

560

22.0

Weight

kg

lbs.

Net

17

37.5

Other

Programmable Interface –
GPIB: 24-Pin IEEE488.1 connector.
Ethernet: 10Base-T, RJ-45 connector.
Keyboard Connector: 6-Pin mini-DIN connector.

Ordering Information

AWG610

2.6 GS/s, Single-channel arbitrary
waveform generator.

Includes: User manual (071-0554-05), program-
mer manual (071-0555-01), GPIB programming
examples disk (063-3216-01), sample waveform
library disk (063-3217-00), performance verification
disk (063-3218-00), power cable, fuse
(159-0407-00).

Please specify power plug when ordering.

Recommended Accessories

Service Manual – Order 071-0556-02.

Protective Cover – Order 200-3696-01.

AC Current Probe (Transformer) – 1 GHz:
Order CT1.

AC Current Probe (Transformer)– 200 MHz:
Order CT2.

AC Current Probe (Transformer)– 2 GHz:
Order CT6.

GPIB Cable – Order 012-0991-01.

50 Ω BNC Cable – Order 012-1341-00.
50 Ω BNC Cable – Order 012-1256-00.
50 Ω SMB Cable – Order 012-1458-00.
50 Ω SMB-to-BNC Cable – Order 012-1459-00.
50 Ω BNC Termination – Order 011-0049-01.
50 Ω BNC Power Divider – Order 015-0660-00.
50 Ω SMA Cable (20 inches) – Order
174-1427-00.

50 Ω SMA Cable (1.0 m) – Order 174-1341-00.
50 Ω SMA Cable (60 inches) – Order
174-1428-00.

SMA Precision Cable (1 ns) – Order
015-0562-00.

SMA Precision Cable (2 ns) – Order
015-0560-00.

SMA Precision Cable (5 ns) – Order
015-0561-00.

SMA T Connector – Order 015-1016-00.

50 Ω SMA Termination – Order 015-1022-00.
50 Ω SMA Power Divider – Order 015-1014-00.
SMA(Ma) - BNC(Fe) Connector – Order
015-0554-00.

SMA(Fe) - BNC(Ma) Connector – Order
015-0572-00.

SMA Kit – Order 020-01693-00.

400 MHz BNC Low-pass Filter – Order
015-0659-00.

200 MHz BNC Low-pass Filter – Order
015-0658-00.

100 MHz BNC Low-pass Filter – Order
015-0657-00.

Instrument Cart – Order K420.

Rackmount Conversion Kit – Order
016-1675-01.

Options

Opt. 1O – Flash disk (78 MB) remove HDD and
STBY switch. (Opt. 10 is best suited for ATE and
system usage requiring 7x24 hour operation.)

Opt. 1R – Rackmount.

Power Plug Options

Opt. A0 – US Plug, 115 V, 60 Hz.

Opt. A1 – Euro Plug, 220V, 50 Hz.

Opt. A2 – UK Plug, 240V, 50 Hz.

Opt. A3 – Australian Plug, 240V, 50 Hz.

Opt. A4 – N. American Plug, 240V, 50 Hz.

Opt. A5 – Swiss Plug, 220V, 50 Hz.

Service

Opt. C3 – Calibration Service 3 Years.

Opt. C5 – Calibration Service 5 Years.

Opt. D1 – Calibration Data Report.

Opt. D3 – Calibration Data Report 3 Years
(with Option C3).

Opt. D5 – Calibration Data Report 5 Years
(with Option C5).

Opt. R3 – Repair Service 3 Years.

Opt. R5 – Repair Service 5 Years.

Warranty

One year parts and labor.

Signal Sources

www.tektronix.com/signal_sources

3