Data Sheet
HDST1 HD-SDI Stress Test Module
Input
Connector –
75 Ω BNC Connector.
Input Signal –
HD-SDI signal.
Bit Rate –
1.485 Gb/s, 1.485/1,001 Gb/s.
Amplitude –
800 mV
p-p
±10%.
Standards Conformance –
SMPTE 292M.
Return Loss –
≤15 dB to 742.5 MHz, ≤10 dB to 1.485 GHz.
Stress Output
Connector –
75 Ω BNC Connector.
Output Signal –
HD-SDI signal.
Amplitude –
80 to 1040 mV
p-p
±5% (measured at 4.64 MHz square wave).
Amplitude Setting –
1% step.
Duty Cycle –
40% to 60%.
Rise/Fall Time –
≤270 ps (20% to 80%).
Return Loss –
≤15 dB to 1.485 GHz.
Jitter
HF Jitter
Jitter Waveform –
Sine wave.
Frequency –
0.1 Hz to 10 MHz.
Amplitude –
0.01 to 1 UI.
Amplitude Setting –
0.01 UI.
Amplitude Error –
≤0.1 UI (≤ 1 MHz, at 1 UI setting).
≤0.1 UI ±5% (≤5 MHz, at 1 UI setting).
≤0.1 UI ±10% (≤10 MHz, at 1 UI setting).
LF Jitter
Jitter Waveform –
Sine wave.
Frequency –
0.1 Hz to 10 kHz.
Amplitude –
0.01 to 20 UI.
Amplitude Setting –
0.01 UI.
Amplitude Error –
≤0.1 UI ±1% (≤1 kHz, at 8 UI setting).
≤0.1 UI ±5% (≤5 kHz, at 8 UI setting).
≤0.1 UI ±10% (≤10 kHz, at 8 UI setting).
Error Insertion
Error Rate –
0 to 120 errors/second.
Error Rate Setting –
0.1 errors/second.
Cable Simulator
Connector –
75 Ω BNC Connector.
Cable Type –
L-5CFB.
Return Loss –
≤15 dB to 1.485 GHz.
Length –
20 m, 100 m.
AGL1 Analog Genlock Module
Inputs –
Two 75 Ω loopthrough; one 75 Ω terminating.
Loopthrough Inputs –
Input range: ±6 dB from nominal black burst.
Return loss: ≥40 dB to 5 MHz.
Burst lock stability:
Amplitude changes: ≤1 ns change over a ±3 dB input level.
Jitter: ≤1 ns with ≥50 dB S/N ratio on a nominal amplitude reference input.
Typically ≤1°.
CW Input –
Input range: 1 to 2.25 V
p-p
.
Frequencies: NTSC and PAL F
sc
; 1, 5, and 10 MHz.
Return loss: ≥30 dB to 10 MHz.
Lock stability:
Amplitude changes: ≤1 ns over the valid input range.
Jitter: ≤1 ns with ≥50 dB S/N ratio for a 2 V reference input. Typically ≤0.5°.
Timing Adjustment (Black burst reference) –
Range: Anywhere within the color frame.
Resolution: ≤0.5°.
Color Framing –
Correct for up to ±45° SCH error on the reference input.
Power Source
Mains Range –
Voltage: 87 to 132 or 174 to 250 VAC.
Frequency: 50 to 60 Hz.
Power Consumption –
Typically 220 W for a fully loaded TG2000 mainframe.
Environmental
Temperature –
Operating: 0 °C to +40 °C.
Nonoperating: -40 °C to +65 °C.
Certifications
EMC –
Certified to the EMC Directive 89/336/EEC.
Safety –
Approved to: CSA1010.1, ANSI S82.01.
Complies with: EN61010-1, IEC1010-1.
Physical Characteristics
Dimensions
mm
in.
Height
133
5.23
Width
483
19.0
Depth
584
23.0
Weight
kg
lb.
Net
17.3
38.0
Shipping
23.7
52.0
4