10 kHz to 400 MHz 110 Watt
Class a BroadBand aMplifier
CBa 400M-110
Technical specifications
Frequency range
10 kHz to 400 MHz
Rated output power
100 W minimum
Output power at 1 dB gain compression
80 W minimum
110 W typical below 100 MHz
Gain (nominal)
51 dB
Third order intercept point
1
61 dBm
Gain variation with frequency
±2 dB
Harmonics at 80 W output power
Better than -20 dBc
Output Impedance
50 Ohms
Stability
Unconditional
Output VSWR tolerance
2
Infinity:1
Input VSWR
2:1
RF connector style
Input
Type N female
Output
Type N female
Safety interlock
Dual input, O/C and/or S/C to mute
USB interface
Optional
Supply voltage
100 to 240 Vac (+/- 10%)
Supply frequency range
45 to 63 Hz
Supply power
<1 kVA (typical 700 VA)
Mains connector
Appropriate IEC 60309 plug (see options)
Conducted and radiated emissions
EN61326 Class A
Conducted and radiated immunity
EN61326: 1997 table 1
Mains harmonic currents
EN61000-3-2
Voltage fluctuations and flicker
EN61000-3-3
Safety
EN61010-1
Case dimensions
19 inch, 4U case, 440 mm deep
Mass
18 kg
Operating temperature range
0 to 40°C
Options (select at time of ordering)
341-745
Bench model with front panel mounted input/output connectors
341-845
Rack mountable with front panel mounted input/output connectors
341-945
Rack mountable with rear panel mounted input/output connectors
Notes:
1. The third order intercept point is a nominal value, as its calculation depends upon the power level at
which distortion measurements are made.
2. Output VSWR tolerance is specified for excitation within the permitted levels and frequency range.
© July 2011 Teseq
®
Specifications subject to change without notice.
Teseq
®
is an ISO-registered company. Its products
are designed and manufactured under the strict
quality and environmental requirements of the ISO
9001. This document has been carefully checked.
However, Teseq
®
does not assume any liability for
errors or inaccuracies.
Teseq AG
Nordstrasse 11F 4542 Luterbach Switzerland
T + 41 32 681 40 40 F + 41 32 681 40 48
[email protected]
www.teseq.com
691-278A August 2011