beautypg.com

Atec Teseq-Schaffner-CBA400M-110 User Manual

Page 2

background image

A d v a n c e d Te s t S o l u t i o n s f o r E M C

10 kHz to 400 MHz 110 Watt

Class a BroadBand aMplifier

CBa 400M-110

Technical specifications

Frequency range

10 kHz to 400 MHz

Rated output power

100 W minimum

Output power at 1 dB gain compression

80 W minimum

110 W typical below 100 MHz

Gain (nominal)

51 dB

Third order intercept point

1

61 dBm

Gain variation with frequency

±2 dB

Harmonics at 80 W output power

Better than -20 dBc

Output Impedance

50 Ohms

Stability

Unconditional

Output VSWR tolerance

2

Infinity:1

Input VSWR

2:1

RF connector style
Input

Type N female

Output

Type N female

Safety interlock

Dual input, O/C and/or S/C to mute

USB interface

Optional

Supply voltage

100 to 240 Vac (+/- 10%)

Supply frequency range

45 to 63 Hz

Supply power

<1 kVA (typical 700 VA)

Mains connector

Appropriate IEC 60309 plug (see options)

Conducted and radiated emissions

EN61326 Class A

Conducted and radiated immunity

EN61326: 1997 table 1

Mains harmonic currents

EN61000-3-2

Voltage fluctuations and flicker

EN61000-3-3

Safety

EN61010-1

Case dimensions

19 inch, 4U case, 440 mm deep

Mass

18 kg

Operating temperature range

0 to 40°C

Options (select at time of ordering)
341-745

Bench model with front panel mounted input/output connectors

341-845

Rack mountable with front panel mounted input/output connectors

341-945

Rack mountable with rear panel mounted input/output connectors

Notes:
1. The third order intercept point is a nominal value, as its calculation depends upon the power level at
which distortion measurements are made.
2. Output VSWR tolerance is specified for excitation within the permitted levels and frequency range.

© July 2011 Teseq

®

Specifications subject to change without notice.
Teseq

®

is an ISO-registered company. Its products

are designed and manufactured under the strict
quality and environmental requirements of the ISO
9001. This document has been carefully checked.
However, Teseq

®

does not assume any liability for

errors or inaccuracies.

Teseq AG
Nordstrasse 11F 4542 Luterbach Switzerland
T + 41 32 681 40 40 F + 41 32 681 40 48
[email protected]

www.teseq.com

691-278A August 2011