Meters, Monitors,

Controls & Indicators

Meters:

Helix

Current

Filament Elapsed Time (Option H)

Monitors:

RF Output Sample (Option E)


Controls:

Mains Power ON/OFF

High Voltage ON/OFF – Fault Reset

Local/Remote

(Option

G)

RF Attenuator (Option B)

Indicators:

• Mains Power ON

• Helix Current Fault

• Filament Time Delay

• TWT Over-temperature

• Standby

• External Interlock Fault (option G)

• High Voltage On

• Remote Control (option G)

• Summary Fault

• Reflected Power Fault (option M)

• Cover Interlock Fault

• Power Supply Fault





Mechanical &

Environmental

Ambient Temperature:

0 to 50°C


Relative Humidity:

to 95% non Condensing


Altitude:

to 10,000 feet max. Derate temperature 2°C/1,000 feet
above 4,000 feet.


Shock & Vibration:

As normally encountered in a protected engineering
laboratory environment.


Cooling:

Forced air with integral blower, air intake and exhaust in
rear.

RF Connectors:

Type N(female), on rear panel (front panel w/Option j)

Frequency

(GHz)

Type

1-2 N

(female)

2-4 N

(female)

4-8 N

(female)

8-12.4 UG-39/U

(WR-90)

12.4-18 UG-419/U

(WR-62)

8-18

MIL-F-39000/3-74 (WRD-

750)

Prime Power:

115 Vac ±10%, 47-63Hz, single phase

230 Vac (option K)


Power Consumption:

1900 Watts for 100W TWT models

2400 Watts for 200W TWT models


Dimensions:
12.25”H x 19”W x 24”D

Weight:

195 Lbs./ 89 Kg.