Specifications and Ordering Information

Thermo Scientific DCT7088 Portable, Digital-Correlation, Transit-Time Flowmeter

Performance Specifications
Velocity Range

±0 to 12 m/s (±0 to 40 ft/s)

Accuracy

±0.5% of velocity or ±0.03 m/s (±0.1 ft/sec)

Sensitivity

0.003 m/s (0.01 ft/sec) at any flow rate including zero

Pipe Size

25.4 mm to 5 m (1 in to 200 in); For line sizes smaller than 2 inches, consult Thermo Fisher Scientific

Functional Specifications
Outputs

4-20 mA (into 1K to 5K Ohms), isolated; RS232 serial interface

Power Supply

Built-in lead acid gel battery: 16-hour continuous operation
90-264 VAC, 50-60 Hz standard with AC adapter/battery charger

Keypad

19-key with tactile action

Display

40-character, two-line, alphanumeric, backlit LCD; screens include present and total flow, velocity, signal strength and Delta T

Data Logger

Greater than 40,000 data points, time stamped; programmable in one second intervals

Temperature Range

Standard transducers: -40°C to +100°C (-40°F to +212°F)
Transmitter: -20°C to +60°C (-5°F to +140°F)
for higher temperature, consult Thermo Fisher Scientific

Physical Specifications
Transmitter

355.6 mm (14 in) W x 342.9 mm (13.5 in) H x 152.4 mm (6 in) D
IP66, waterproof against accidental immersion and splash-proof with lid closed

Transducers

Encapsulated design

Cable Length

5 m (16 ft) standard

Weight

Approximately 6.8 kg (15 lb) with 16-hour battery

Process Instruments

www.thermoscientific.com

Unit 702-715, 7/F Tower West
Yonghe Plaza No. 28, Andingmen East Street
Beijing 100007 CHINA

A-101, ICC Trade Tower, Senapati Bapat Road
Pune 411016 Maharashtra INDIA

Ion Path, Road Three,
Winsford, Cheshire CW7 3GA UK

1410 Gillingham Lane
Sugar Land, TX 77478 USA

+86 (10) 8419-3588
+86 (10) 8419-3580 fax

+91 (20) 6626 7000
+91 (20) 6626 7001 fax

+44 (0) 1606 548700
+44 (0) 1606 548711 fax

+1 (800) 437-7979
+1 (713) 272-0404
+1 (713) 272-4573 fax

© 2010 Thermo Fisher Scientific Inc. All rights reserved. Windows and Microsoft are registered trademarks of Microsoft Corporation in the United States and/or other countries.
Results may vary under different operating conditions. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your
local sales representatives for details. Literature Code PI.2055.0710

DCT7088 2 16

MODEL NUMBER

BA
TTER

Y DURA

TION

TRANSDUCER CABLE LENGTH

TRANSDUCER CABLE LENGTH

16:

16 ft (5 m) length cable (standard)

50:

50 ft (15 m) length cable

H30: High-temperature transducers with 30 ft (9 m) cable
H50: High-temperature transducers with 50 ft (15 m) cable

BATTERY DURATION

2: 16-hour battery

MODEL NUMBER

DCT7088: Thermo Scientific DCT7088

Portable Transit-Time Flowmeter

Ordering Information

Thermo Scientific UltraScan Software
While the DCT7088 flowmeter can be set up using its integral
keypad, Thermo Scientific UltraScan configuration and signal
analysis software simplifies the process by providing easy-to-use
menus. In addition to configuration, this Microsoft

®

Windows

®

-

based program provides access to the flowmeter’s extensive
waveform diagnostics, enabling users to easily determine the best
location for transducer installation. With UltraScan, data can be
downloaded to one or more instruments, eliminating the need
to individually program multiple meters. It also enables paperless
flow rate data archival, simplifying retention and reporting
requirements for ISO 9000, OSHA and FDA compliance.

Thermo Scientific Ultrasonic Thickness Gauge
The Thermo Scientific Ultrasonic Thickness Gauge (UTG) is a compact,
rugged device that enables DCT7088 flowmeter users to determine
the pipe wall thickness from the outside of the pipe. It can also be
used to measure the corrosion or erosion of storage tank walls.