C-evo, Tenney, Standard features – Atec Tenney-C20RC User Manual
Page 2: Versatouch
![background image](/manuals/319854/2/background.png)
C-EVO
Standard
Features
• VersaTouch
TM
controller
• Ethernet port
• USB port
• Heated viewing glass window
• Chamber light
• Two 3” cable ports
• Solid state humidity sensor
• Platinum RTD temperature sensor
• Heavy duty leveling casters
• Nichrome wire air heater
• Solid state pressure switches
• Thermal expansion valves
• FM approved safety OTP
• Backup safety thermal cutoff
• Main electrical disconnect LOTO
• Chamber vent port
• One shelf standard
• UL 508A compliant
All technical data specified for units with standard equipment. All figures are typical average values for C-EVO Series
devices. SPX Thermal Product Solutions reserves the right to alter technical specifications at any time. Data may vary
depending on ambient conditions, product load, or other changes causing interference to chamber airflow.
Specifications and Product Information is subject to change without notice. Images for reference only. Some options and
accessories may not be included with all configured models.
Model
C10S
C10C
C10RS
C10RC
C20S
C20C
C20RS
C20RC
C30S
C30C
C30RS
C30RC
Cubic Feet
10
20
30
Liters
283
566
850
Work Space (W x D x H)
24" x 26" x 28" / 61cm x 66cm x 71cm
30" x 32" x 36" / 76cm x 81cm x 91cm
36" x 40" x 36" / 91cm x 102cm x 91cm
Exterior (nominal) (W x D x H)
32" x 58" x 68" / 81cm x 147cm x 173cm
38" x 64" x 76" / 97cm x 163cm x 193cm
44" x 72" x 76" / 111cm x 183cm x 193cm
Unit Weight (LBS)
1000
1154
1000
1154
1100
1254
1100
1254
1250
1350
1250
1350
Temperature Range
-35°C
-73°C
-35°C
-73°C
-35°C
-73°C
-35°C
-73°C
-35°C
-73°C
-35°C
-73°C
200°C
200°C
200°C
200°C
200°C
200°C
200°C
200°C
200°C
200°C
200°C
200°C
Humidity Range *
-
-
10% - 95%RH 10% - 95%RH
-
-
10% - 95%RH 10% - 95%RH
-
-
10% - 95%RH 10% - 95%RH
Cooling Rate (empty chamber) Min (C/Min)
180C to -65C
72 (3.4)
72 (3.4)
111 (2.2)
111 (2.2)
136 (1.8)
136 (1.8)
125C to -40C
37 (4.5)
37 (4.5)
53 (3.1)
53 (3.1)
63 (2.6)
63 (2.6)
85C to -20C
22 (4.8)
22 (4.8)
33 (3.2)
33 (3.2)
40 (2.6)
40 (2.6)
85C to -40C
30 (4.1)
30 (4.1)
45 (2.8)
45 (2.8)
54 (2.3)
54 (2.3)
ambient to -40C
15 (4.3)
15 (4.3)
23 (2.8)
23 (2.8)
28 (2.3)
28 (2.3)
ambient to -68C
40 (2.3)
40 (2.3)
66 (1.4)
66 (1.4)
85 (1.1)
85 (1.1)
Heating Rate (empty chamber) Min (C/Min)
-65C to 180C
42 (5.9)
42 (5.9)
64 (3.8)
64 (3.8)
84 (2.9)
84 (2.9)
-40C to 125C
28 (6)
28 (6)
42 (3.9)
42 (3.9)
50 (3.3)
50 (3.3)
-20C to 85C
18 (6)
18 (6)
26 (4)
26 (4)
32 (3.3)
32 (3.3)
-40C to 85C
21 (6)
21 (6)
31 (4)
31 (4)
38 (3.3)
38 (3.3)
-34C to ambient
10 (6.2)
10 (6.2)
10 (6.2)
10 (6.2)
14 (4.2)
14 (4.2)
14 (4.2)
14 (4.2)
17 (3.5)
17 (3.5)
17 (3.5)
17 (3.5)
-68C to ambient
15 (6.2)
15 (6.2)
22 (4.2)
22 (4.2)
27 (3.5)
27 (3.5)
Live Load Watts @ -18C
1200
1700
1200
1700
1160
1650
1160
1650
1120
1610
1120
1610
Live Load Watts @ -40C
-
1400
-
1400
-
1330
-
1330
-
1260
-
1260
Live Load Watts @ -54C
-
1100
-
1100
-
1010
-
1010
-
940
-
940
Temperature Control
±0.3°C
after stabilization
±0.3°C
after stabilization
±0.3°C
after stabilization
Temperature Uniformity
±2°C @ 65°C
±2°C @ 65°C
±2°C @ 65°C
Humidity Control
-
-
±2% RH
±2% RH
-
-
±2% RH
±2% RH
-
-
±2% RH
±2% RH
Air Flow Rate
500 CFM
500 CFM
500 CFM
Heat Capacity
3KW
3KW
3KW
Humidifier Capacity
-
-
2KW
2KW
-
-
2KW
2KW
-
-
2KW
2KW
Refrigeration
2 HP
(2) 2 HP
2 HP
(2) 2 HP
2 HP
(2) 2 HP
2 HP
(2) 2 HP
2 HP
(2) 2 HP
2 HP
(2) 2 HP
Condenser
Air Cooled - Std Water Cooled - Option
Air Cooled - Std Water Cooled - Option
Air Cooled - Std Water Cooled - Option
Power
208V - 230V 1P 60Hz
208V - 230V 1P 60Hz
208V - 230V 1P 60Hz
Amp - Fuse
40
60
50
60
40
60
50
60
40
60
50
60
Amp - Under Load
32
45
40
45
32
45
40
45
32
45
40
45
Power
460V 1P 60Hz
460V 1P 60Hz
460V 1P 60Hz
Amp - Fuse
20
30
30
30
20
30
30
30
20
30
30
30
Amp - Under Load
16
23
20
23
16
23
20
23
16
23
20
23
Performance estimates based on 230v 1P 60Hz
*Humidity Range: based on temperature range 20°C to 85°C limited by 3°C dewpoint
Tenney
www.tenney.com/c-evo