Cool Down Transition Time (empty)*

Heat Up Transition Time (empty)*

Programmable Controller

Up to 256 steps can be programmed into as
many as 40 nameable profiles. The context
sensitive information key and guided steps
make profile programming fast and easy. A
four-line backlit LCD displays programming,
setup, operating and help information. A
large LED readout indicates the actual
chamber temperature with 0.1° resolution.
Internal logic provides refrigeration
compressor control for responsive and
reliable performance. Includes an RS-232
interface. Optional GPIB interface is
available.

High/Low Limit Controller

Provides independent protection against
excess temperatures. Both high and low
limits can be set. The limit controller will
shut down the chamber in the event of an out
of limit condition.

Model

105A Half Cube

Temperature Chamber

Also Available for Rent

TestEquity LLC

2450 Turquoise Circle
Thousand Oaks, CA 91320

800-732-3457
805-498-9933

www.testequity.com

©TestEquity 8.06

Chamber Performance

Temperature Range

-40°C to +130°C

Control Tolerance

±0.5°C (±0.2°C Typical)

(

Measured at the control sensor after stabilization)

Uniformity

±1.0°C (±0.5°C Typical)

(Variations throughout the chamber after stabilization)

Live Load Capacity

+23°C 0°C

-10°C -20°C -30°C -40°C

200 Watts 175 Watts 165 Watts 145 Watts 90 Watts 10 Watts

End Temp

Start
Temp

+23°C

+50°C

+85°C

+23°C

-------

1.5 min

6 min

0°C

2 min

4 min

7.5 min

-20°C

3 min

5 min

8 min

-40°C

4.5 min

7.5 min

11 min

End Temp

Start
Temp

Rate of Change:

To calculate rate of change for a particular condition, take the difference

between the Start Temp and End Temp and divide by the Transition Time.
Cool Down Example (empty):

From +85°C to -20°C = 105°C / 17 min = 6.18°C/min.

Heat Up Example:

From -40°C to +85°C = 125°C / 11 min = 11.36°C/min.

* Note:

Transition times are measured after a 30 minute soak at the respective start temperature.

Physical Characteristics and Safety

Inside Dimensions

12" W x 9" H x 8" D (0.5 cubic feet)

Outside Dimensions

16.5" W x 26" H x 20" D (nominal)

Door latch adds 2" to width.
Circulator motor housing adds 1" to depth in rear.

Min. Installed Clearance

12" from the rear.

Access Ports

2" Port on left and right side (two total)
Supplied with silicone foam plugs

Weight

Chamber Weight: 114 pounds
Shipping Weight: 140 pounds

Safety

Designed to meet UL STD 3101-1
and CAN/CSA STD C22.2 No. 1010.1

+23°C

0°C

-10°C

-20°C

-30°C

-35°C

-40°C

+23°C

-------

3 min

5 min

7 min 10 min 13 min 22 min

+85°C

8 min 13 min 15 min 17 min 20 min 23 min 31 min

Power Requirements

Note:

Performance is typical and based on operation at 23°C (73°F) ambient and nominal

input voltage. Designed for use in a normal conditioned laboratory. Operation at higher
ambient temperatures will result in decreased cooling performance. Low end limit
derates to -38°C when operating above 27°C (80°F) ambient. Operation above 30°C
(85°F) or below 16°C (60°F) ambient is not recommended.

Refrigeration and Heating System

Compressor

1/3 HP Copeland hermetic

Condenser

Air Cooled

Heater Power

500 Watts

Input Voltage

120 V nominal (110 to 126 VAC), 60 Hz, 1 PH

Current Draw

Max Current Draw 10 A, Recommended Service 15 A.

Instrumentation

Temperature Controller

256 steps, 40 profiles, ramp and soak programmable
memory. RS-232C interface.

Limit Controller

Independent high and low temperature limits, user
adjustable.

Plugs Into Any 120V Outlet

The Half Cube draws only 10 Amps
maximum at 120 Volts. You can plug it
into any standard wall receptacle, with
plenty of power to spare for other
equipment.

Reversible Chamber Door

You won’t need to rearrange your whole
bench or workflow to accommodate the
Half Cube. The chamber door is
reversible, allowing the door to open
from the left or right side. This is also
useful when placing two Half Cube
chambers side-by-side.

Shown on
optional
cart.

Available Options

GPIB Interface
Extra Shelf
Rackmount Adapter
50 Hz Export Version
Cart