beautypg.com

Manual surge coupling network – Atec Teseq-Schaffner-CDN3083-S100M User Manual

Page 2

background image

A d v a n c e d Te s t S o l u t i o n s f o r E M C

MANUAL SURGE COUPLING NETWORK

CDN 3083-S100M

Teseq AG
Nordstrasse 11F 4542 Luterbach Switzerland
T + 41 32 681 40 40 F + 41 32 681 40 48
[email protected]

www.teseq.com

691 – 157A May 2008

The CDN 3083-S100 set:

1 x Surge decoupling network CDN 3083-S100 N – L1

1 x Surge decoupling network CDN 3083-S100 L2 – L3

2 x Earth rail

1 x Allen key isolated

1 x User Manual CDN 3083 E

1 x Test certifi cate

1 x Wheel set

2 x Connection tables, laminated

IEC coupling set

1 x INA 3080 Surge coupling unit

ANSI coupling set/optional IEC coupling

2 x INA 3080 Surge coupling unit

1 x Connection cable

Depending on generator used, following complementary items are in the set:

NSG 2050 generator system

1 x INA 3085 Synchronisation unit for NSG 2050 system

2 x Cable 1 m, with Fischer/Lemo connectors

1 x Dummy plug for NSG 2050 generator

NSG 3040 and Modula

1 x INA 3084 Synchronisation unit for NSG 3040 family

2 x Cable 1 m, with each a Fischer/Fischer connectors

Pulse voltages/current

8 kV/4 kA max.

EUT power supply

Line-to-line or line-to-PE 620 Vrms; (max.440 Vrms for NSG 3040
and Modula) per Phase 100 A nom. continuous current; 0 – 60 Hz
(max. 400 Hz with power loses)

EUT connectors

Screw-terminals, 230 A, up to 110 mm

2

, AWG 4-4/0

Max. Temperature

70°C

Decoupling conditions

As per IEC 61000-4-5 and ANSI C62.45

Coupling modes

Surge Differential, Lines to PE, Common to PE (with ANSI coupling
set or with optional INA 3080 for IEC)

Dimensions

850 x 520 x 345 mm (L x D x H)

Weight

80 kg approx.

Optional accessories

INA 3080 Surge coupling unit
MD 300 Current measuring probe
MD 200/200A Voltage measuring probe