Manual surge coupling network – Atec Teseq-Schaffner-CDN3083-S100M User Manual
Page 2

A d v a n c e d Te s t S o l u t i o n s f o r E M C
MANUAL SURGE COUPLING NETWORK
CDN 3083-S100M
Teseq AG
Nordstrasse 11F 4542 Luterbach Switzerland
T + 41 32 681 40 40 F + 41 32 681 40 48
[email protected]
www.teseq.com
691 – 157A May 2008
The CDN 3083-S100 set:
1 x Surge decoupling network CDN 3083-S100 N – L1
1 x Surge decoupling network CDN 3083-S100 L2 – L3
2 x Earth rail
1 x Allen key isolated
1 x User Manual CDN 3083 E
1 x Test certifi cate
1 x Wheel set
2 x Connection tables, laminated
IEC coupling set
1 x INA 3080 Surge coupling unit
ANSI coupling set/optional IEC coupling
2 x INA 3080 Surge coupling unit
1 x Connection cable
Depending on generator used, following complementary items are in the set:
NSG 2050 generator system
1 x INA 3085 Synchronisation unit for NSG 2050 system
2 x Cable 1 m, with Fischer/Lemo connectors
1 x Dummy plug for NSG 2050 generator
NSG 3040 and Modula
1 x INA 3084 Synchronisation unit for NSG 3040 family
2 x Cable 1 m, with each a Fischer/Fischer connectors
Pulse voltages/current
8 kV/4 kA max.
EUT power supply
Line-to-line or line-to-PE 620 Vrms; (max.440 Vrms for NSG 3040
and Modula) per Phase 100 A nom. continuous current; 0 – 60 Hz
(max. 400 Hz with power loses)
EUT connectors
Screw-terminals, 230 A, up to 110 mm
2
, AWG 4-4/0
Max. Temperature
70°C
Decoupling conditions
As per IEC 61000-4-5 and ANSI C62.45
Coupling modes
Surge Differential, Lines to PE, Common to PE (with ANSI coupling
set or with optional INA 3080 for IEC)
Dimensions
850 x 520 x 345 mm (L x D x H)
Weight
80 kg approx.
Optional accessories
INA 3080 Surge coupling unit
MD 300 Current measuring probe
MD 200/200A Voltage measuring probe