Subject to technical changes, especially to improve the product, at any time without prior notification.

Other data
Electromagnetic compatibility

IEC61000 (EN61000), EN50081, EN50082

Protection system

IP20 in accordance with DIN40050

Operating/storage temperature

0...40°C, -20...50°C

Climatic class

KYG in accordance with DIN40040

Power supply

85...264V, 47...440Hz, about 30W

PSU600
Precision current transformer, max. 600A,
ü=1500:1, DC to >100kHz,
accuracy <(0.01%MV+0.005%MR)

Accessories

PSU600-K3-L95
Adapter-/supply cord to connect the
PSU600 to the measuring sockets „I-I*“
of LMG95.
For currents >50A to 600A

PSU600-BUR15
Adapter with precision burden and
supply cord to connect the PSU600 to
the measuring socket „Ext. Shunt“.
For currents >1A bis 600A

LMG95 Application Software

LVDRV-L95

LMG95 driver for LabVIEW 5.1, for RS232- and IEEE488-interface, with software examples

LWINDRV-L95

LMG95 driver for LabWindows/CVI, for RS232- and IEEE488-interface, with software examples

SYS61K-1-SOFT

Controlling-/data logging-/evaluation software for long time test of harmonics and flicker
according with IEC61000-3-2/-3 with the LMG95

TERM-L5

Data transfer from LMG95/450 to PC via RS232- and IEEE488-interface, recording as ASCII in Microsoft Excel- (CSV) or ZES-format,
or in tables with any separator, visualisation in real time of some selectable measurement values

L95-SH-100
Shunt to measure small currents up
to 1A, to be connected to the measuring
socket „Ext. Shunt“ of LMG95.
Customer specific design

L95-Z06
HF-summing current transformer with
burden resistor for current measurements
without effecting measure circuitry,
e.g. at discharging lamps.

L95-SCAN30
Scanner with internal shunts to measure
15 respectively 30 devices under common
supply. Sequential measuring.
Enhancement of the LMG95 to a multi
channel device

HST6-1, HST6-2, HST12-1, HST12-2
Precision high voltage devider for 6/12kV.
Single pole isolated high voltage
measuring (-1), dual pole isolated high
voltage measuring (-2). Accuracy:
0.05% (45-65Hz), 0.3% (DC-100kHz)

MAS1
U-/I- measuring adapter for devices with
„Schuko“plug (Grounding outlet)

MAK1
U-/I- measuring adapter for devices with
inlet connector (non-heating appliances)

L95-Z01
Mounting kit for 19“ rack mounting

L95-Z09
Measuring sockets on rear side,
e.g. when rack mounted

LMG95-REF High precision standard,
basic accuracy 0.015%. Traceable with
calibration certificate by PTB (National
Institute of Standards in Germany)

Special versions and designs

KR-L95
Calibration Certificate,
traceable to ISO9000

NDL5 Longtime-data logging to harddisk
for LMG95/450. Communication via
Internet/Ethernet, even when recording

WR-24-230
Inverter 24VDC to 230VAC/50Hz for
supply of LMG instruments