ZES ZIMMER provides the system CE-Test61k for compli-
ance tests corresponding to standards EN 61000-3-2, -3,
-11 and -12. The precision power analyzers

LMG95 and

LMG500 comply with the standards for measurement
devices EN 61000-4-7 for harmonic analyzers and standard
EN 61000-4-15 for flicker meters. For validating the con-
firmation to the standards for current harmonics, the device
under test must be fed by a power source with a purely
sinusoidal and stable output voltage. This is essential in
order to proof that the measured current harmonics are
generated by the device under test and do not originate
from the source. Therefore the

ZES ZIMMER LMG devices

test the voltage stability and that distortions by harmonics
are within permissible limits during each analysis interval.

In addition to a power source, the flicker test requires a
well-defined reference impedance. Flicker is determined
by the amplitude and occurrences of line voltage fluctua-
tions. Voltage fluctuations are the result of current varia-
tions induced by the consuming device at the reference
impedance. In order to obtain results which can be com-
pared with others, a normalized line impedance must be
inserted between the feeding source and the test sample
when measuring flicker. The impedance values for these
reference impedances are defined as (0.24+j0.15)

Ω in the

phases and (0.16+j0.10)

Ω in the neutral. The test soft-

ware allows to record all device settings and measured
data and to process them into a test protocol that is man-
datory for the CE declaration.

Device classes according to EN61000-3-2

Current Harmonics

Flicker

Current range

Frequency range

Test standard

Measurement device

standard for current

harmonics analyzers

Test standard

Measurement

device standard

for flicker meter

up to 16 A

up to 2 (2.4) kHz,

i.e. up to the 40th

harmonics at 50

(60) Hz

EN 61000-3-2

EN 61000-4-7

EN 61000-3-3

EN 61000-4-15

16 A to 75 A

EN 61000-3-12

---

0 to 75 A

2 (2.4) to 9 kHz

---

EN 61000-4-7

Annex B

EN 61000-3-11

Standards for testing and measurement devices for line interferences caused by current harmonics, depending on current and frequency
range, and by flicker, depending on current range

Test set-up for measurements according to EN61000-3, 3-phase

Device class

Type of device

Class A

Symmetric three-phase devices

Home appliances, except devices that

belong to class D

Electrical tools, except portable

electrical tools

Dimmer for bulbs

Audio equipment

Devices that do not match classes B,

C or D

Class B

Portable electrical tools

Arc-welding equipment for private use

Class C

Lighting equipment

Class D

Devices of the following type of which the

power goes below or equals 600 W:
- PCs and monitors for PCs
- TV sets or radio receivers

G~

G~

G~

jXA

RA

jXA

RA

jXA

RA

jXN

RN

A

A

A

V

V

V

EUT

Power source

Reference impedance

NI2415-3

Power analyzer LMG500-3

Equipment

under test