beautypg.com

Atec Teseq-JT_5510-JT_5550 User Manual

Page 2

background image

A d v a n c e d Te s t S o l u t i o n s f o r E M C

JT 5510 / JT 5550

JT 5510 TransienT generaTor

JT 5550 Load dump generaTor

Technical information JT 5510

Amplitude

Pulse width

Repetition rate

Standard

Version

Year

Pulse name

Polarity

Min

[V]

Max

[V]

tr

[µs]

td

[µs]

t

[µs]

Ri

[Ω]

Min

[s]

Max

[s]

JASO

D001-94

1994

Pulse A-2

positive

20

110

<1

5.75

2.5

0.4

1

120

JASO

D001-94

1994

Pulse D-2

positive

20

170

<1

5.75

2.5

0.9

1

120

JASO

D001-94

1994

Pulse B-1

negative

20

80

<1

138,000

60,000

8

6

120

JASO

D001-94

1994

Pulse B-2

negative

20

260

<1

4,600

2,000

80

6

120

JASO

D001-94

1994

Pulse E

negative

20

320

<1

60,000

26,000

210

30

120

Nissan

28400 NDS3

1997

Pulse B-1

positive

20

80

<1

46,000

*

*

3

120

Nissan

28402 NDS3

1997

Pulse B-2

negative

20

300

<1

7,600

*

*

3

120

Technical information JT 5550

Amplitude

Pulse width

Repetition rate

Standard

Version

Year

Pulse name

Polarity

Min

[V]

Max

[V]

tr

[µs]

td

[µs]

t

[µs]

Ri

[Ω]

Min

[s]

Max

[s]

JASO

D001-94

1994

Pulse A1

positive

50

110

<1

460

200

0.8

30

60

JASO

D001-94

1994

Pulse D1

positive

50

120

<1

920

400

1.5

30

60

* Pulse width values typical - defined by pulse generation circuit, not by pulse characteristics

Note: The pulse shaping networks are designed internally with a 1 µs rise time. However, due to system capacitance of the
100 A coupler, typical rise times measured at the output of the system can be 3 µs or more.

© February 2011 Teseq

®

Specifications subject to change without notice.
Teseq

®

is an ISO-registered company. Its products

are designed and manufactured under the strict
quality and environmental requirements of the ISO
9001. This document has been carefully checked.
However, Teseq

®

does not assume any liability for

errors or inaccuracies.

Teseq AG
Nordstrasse 11F 4542 Luterbach Switzerland
T + 41 32 681 40 40 F + 41 32 681 40 48
[email protected]

www.teseq.com

691-049A February 2011