Kemz 801a – Atec Teseq-KEMZ-801A User Manual
Page 3

Teseq GmbH
Landsberger Str. 255 · 12623 Berlin · Germany
T + 49 30 56 59 88 35 F + 49 30 56 59 88 34
[email protected]
www.teseq.com
82-255100 E01 Apr. 2012
Test set-up with EUT according IEC/EN 61000-4-6 with EM clamp
Test set-up with EUT according IEC/EN 61000-4-6 with EM clamp and monitoring probe
Model no. and options
Part number
Description
255100
KEMZ 801A
EM Clamp, conform with IEC/EN 61000-4-6
255102
KEMZ 801AS
EM Clamp, conform with IEC/EN 61000-4-6, supplied with calibration
set CAL 801A
255103
KEMZ 801AS50
EM Clamp, conform with IEC/EN 61000-4-6, supplied with calibration
set CAL 801A and 50 Ω termination 1 W
97-235501
KEMZ 801-TC
Traceable calibration (ISO17025), order only with KEMZ 801A
255101
CAL 801A
Calibration unit for KEMZ 801A
AE-side
EUT-side
KEMZ 801
Auxiliary
equipment
150 kHz ... 230 MHz (1000 MHz)
EM-Koppelzange
KEMZ 801
EUT
RF out
Amp in
< +10 dBm
Amp out
ch.1 < +27 dBm
ch.2 < +20 dBm
ch.3 < +20 dBm
Power meter
NSG 4070
Power
USB
Tuning
StSize
StSize
StSize
Local
Back
Stop
Run
Hold
0
.
1
4
7
8
5
2
3
kHz
dBm
6
9
MHz
dBµV
Hz
V
Enter
Step
1
STO
FRQ
LVL
RCL
Step
2
Step
3
MOD
2nd
Help
RF
ON/OFF
EUT
AE
Equipment
under test
Insulating
Ground plane
Insulating
6 dB attenuator
Test generator e.g. Teseq NSG 4070
with built-in RF synthesizer,
brodband power amplifier and
power meter
AE-side
EUT-side
KEMZ 801
Insulating
Ground plane
6 dB attenuator
Auxiliary
equipment
150 kHz ... 230 MHz (1000 MHz)
EM-Koppelzange
KEMZ 801
EUT
RF out
Amp in
< +10 dBm
Amp out
ch.1 < +27 dBm
ch.2 < +20 dBm
ch.3 < +20 dBm
Power meter
NSG 4070
Power
USB
Tuning
StSize
StSize
StSize
Local
Back
Stop
Run
Hold
0
.
1
4
7
8
5
2
3
kHz
dBm
6
9
MHz
dBµV
Hz
V
Enter
Step
1
STO
FRQ
LVL
RCL
Step
2
Step
3
MOD
2nd
Help
RF
ON/OFF
EUT
AE
Equipment
under test
Monitoring probe
Power meter
Insulating
Test generator e.g. Teseq NSG 4070
with built-in RF synthesizer,
brodband power amplifier and
power meter
EM claMp for IEc/EN 61000-4-6
KEMZ 801a
Teseq® is an ISO-registered company. Its products are designed
and manufactured under the strict quality and environmental
requirements of ISO 9001.
This document has been carefully checked. However, Teseq® does
not assume any liability for errors or inaccuracies.
Specifications subject to change without notice.