beautypg.com

Nsg 2070 – Atec Teseq-Schaffner-NSG2070 User Manual

Page 2

background image

IEC 61000-4-6 Test System

Bandwidth:

100kHz - 250MHz

Modulation frequency:

1kHz ± 1%

Step size:

1kHz - 100MHz

Operating modes:

frequency sweep, pulse mode

Sweep modes:

linear, numeric, percentage

Linearity:

< +2dB, calibrated < ± 0.5dB

Input / Output impedance:

50

Hold time:

2ms - 100sec

VSWR:

< 1.5

Dynamic range:

> 58dB

Distortion:

> -17dB (referred to carrier frequency)

RF meter

Output range:

-40dBm ... +10dBm

linearity:

±5%, from 0.166V to 1.66V

Modulation:

amplitude modulation 0 - 100%

Frequency response:

±5%, from 100kHz - 250MHz 80%

+5%

VSWR

< 1.15 from 100kHz - 250MHz

Bandwidth:

100kHz to 250MHz

Distortion:

< -20dB (relative to carrier frequency)

no signal deterioration or ringing

Linearity:

± 1.5dB, with calibration < ± 0.5dB

Input sensitivity:

-40dBm to +10dBm

Power output:

85W max. (saturated)

Input / output impedance:

50

Output VSWR:

<1.2 (including 4dB attenuator)

Load impedance:

from open to short circuit

Housing:

19” benchtop housing with prop feet

Size W x D x H mm

449 x 171 x 461

Weight:

NSG 2070: 16kg approx.

Technical Specifications

Synthesiser NSG 2070

Technical Specifications

Amplifier NSG 2070

Coupling Options
A range of application-specific
coupling/decoupling networks (CDNs) is
offered for use with the NSG 2070, for
power, data and telecom applications.
This coupling method is ideal for
repetitive testing for detailed design
characterisation, or volume compliance
work.
An electromagnetic clamp (EM-clamp)
can be used to couple the signal directly
to any power line or data line. It is not
application-specific, so this coupling
option is a good choice where many
different products are to be tested.
Schaffner's current injection probe is easy
to use and, unlike competitive units, is
capable of coupling signals right up to
IEC 61000-4-6 Level 3. Like the EM-
clamp, the current injection probe can be
used to couple the signal to any power
line or data line.

NSG 2070