beautypg.com

Alternating current output, Resistance measurement, General specifications – Atec Vitrek-930i User Manual

Page 2: Ordering information

background image

Alternating Current Output

Range: 3 to 30 amperes RMS, programmable

Resolution: 1 amp

Output Frequency: Sinewave synthesis,

50Hz to 400Hz

Compliance Voltage: 3 volts RMS

Regulation: ± 0.25% no load to full load

Resistance Measurement

Resistance Limit: User programmable max.

and min. Test is automatically aborted when

limit is exceeded

Resistance Range: 1

at 3 amps linearly

decreasing to 100 m

at 30A

Resistance Resolution: 10µ

Measurement Accuracy: ± 1.0% of reading;

± 0.5% of range

Accuracy: Specifications apply for 1 year, ±

5°C from the cal temp within 20°C to 30°C

Calibration: Certificate of calibration trace-

able to the National Institute of Standards

and Technology (NIST) provided

Test Time: Digital count down timer, pro-

grammable 1 to 9999 seconds

Terminal Configuration: True four-wire kelvin

General Specifications

Remote Interface: VICL and serial

com standard. PLC optional

Display: 40 character dot matrix illuminated

liquid crystal display

Indicators: L.E.D. status indicators

Alarm: Audible and visual alarms provide

pass/fail indication

Diagnostics: Built-in self diagnostics test

ROM, RAM and output system

Safety: CE mark certified to EN61010

Accessories: K-2, VIC-3, BBL-2 and opera-

tors manual supplied with unit

Warranty: Extended 5 year parts and labor

with annual factory calibration and mainte-

nance. Standard warranty one year

Operating Temperature: 0°C to 50°C

Humidity: 90% RH 0°C to 40°C

Power: 115/230 VAC ± 10% 250 VA max

Dimensions: 89mmH x 432mmW x 457mmD

(3.5”H x 17”H x 18”D)

Weight: 11Kg (24 lb.) Net/15Kg (34 lb.)

shipping

Ordering Information

Vitrek 930i Automatic Ground
Integrity Analyzer . . . . . . . . . . . . . . . . . . .

TL115HC Outlet Test Adapter . . . . . . . . . .

K-4 4-wire 4-clip 30A lead set. . . . . . . . . .

K-2 4-wire 2-clip 30A lead set. . . . . . . . . .

RM-1 Rack Mount Adapter Kit . . . . . . . . .

PLC-3 Logic Level Interface . . . . . . . . . . .

RS-1 RS232 Cable 6 ft. . . . . . . . . . . . . . .

VIC-3 930i to 944i 2 Meter
Communication Cable. . . . . . . . . . . . . . . .

OM-930 Extra Operators Manual. . . . . . . .

Represented by:

The 930i shown here with the Vitrek 944i Dielectric Analyzer and TL-115HC Test Adapter. These two
units in tandem provide hipot and ground bond test capability from the touch of a single button.

Vitrek Corporation
www.vitrek.com

9880A Via Pasar – San Diego, CA 92126

Voice: 858-689-2755 Fax: 858-689-2760

Email: [email protected]

Prices and specifications subject to change without notice.
©Copyright 1998. Vitrek Corporation. All rights reserved.
CLC-ILU 50K

Alternating Current Output

Resistance Measurement

General Specifications

Ordering Information

W O R L D L E A D E R S I N C O M P L I A N C E A U T O M A T I O N

S M