PV Analyzer User Interface

PV Model Choices

Performance verification meth-
ods always require comparison of
measured results with a reference
standard. For installed PV arrays,
the standard is a PV model. The

Solmetric PV Analyzer compares

measured and modeled array per-
formance, taking into account the
existing irradiance and temperature.

Three built-in models ensure cover-
age of all types of PV modules:

1. Sandia model

The most comprehensive

PV model

Developed by Sandia

National Laboratories

Based on module

measurements taken in
independent laboratories

Accounts for all performance-

related factors of a PV module

Data for over 400 modules

is included

2. Five-parameter model

Allowing for coverage of a broader
range of PV modules, this ad-
vanced model is derived from mod-
ule data sheet specifications. Data
for over 1700 modules is included.

3. Single-point model

This model predicts the maximum
power voltage and current at the
existing irradiance and tempera-
ture. Based on data sheet values,
this model can be used with almost
any PV module with basic specifi-
cations.

I-V and P-V curves
of a healthy PV
string. Start/Stop
inverter voltage
range is highlighted
in green.

Complete
description of
the PV array
enables accurate
performance
predictions.

I-V and P-V curves
of a string with by-
passed cell strings.

Tabular summary
compares predicted
and measured
results. “Snapshot”
function allows
comparison of
multiple results.