The four V50 Series Electrical Safety Testers allow you to choose the
model with the functions you need without having to pay for the ones
you don’t.

Represented By:

Vitrek Corporation
www.vitrek.com

9880A Via Pasar – San Diego, CA 92126
Voice: 858-689-2755 Fax: 858-689-2760
Email: [email protected]

Storage Temperature: -10°C to 70°C, 70%
RH max
Dimension: 17.6"L x 13"W x 5.9"H,
446(L) x 330(W) x 149(H)mm
Weight: 30 lbs (14kg) net, 34 lbs (16 kg)
ship
Accessories: NIST certification, TL-2050
Test Leads, Instruction Manual and
power cord
Accuracy: Stated specifications apply for
1 year at 23°C ± 5°C
Calibration: Certificate of Calibration,
traceable to NIST provided
Compliance: CE mark certified to EN61010
and EMC directives EN50081-1 &
EN50082-2
Warranty: 3-Year extended warranty with
annual factory calibration, 1 year parts
and labor standard

Ordering Information

QuickTest

TM

Software

Option QT-50: Bundled test automation
software with PC interface adapter and
cable. Easy to load Graphical test sequence
development and operating environment.
Provides time/date, operator, test parame-
ters, and test results for review, printout or
export to database program.

Ordering Information

V50 AC Electrical Safety Tester . . . . . . . . . .
V51 AC/DC Electrical Safety Tester . . . . . . .
V52 AC/IR Electrical Safety Tester . . . . . . . .
V53 AC/DC/IR Electrical Safety Tester . . . . .
QT-50 Bundled Quicktest Software with
PC interface adaptor and cable . . . . . . . . . .
TL-1050 High Voltage Probe Lead Set. . . . .
TL-2050 High Voltage Alligator Lead Set . . .
TL-IEC50 IEC Socket Lead Set . . . . . . . . . .
OM-50 Additional Operators Manual . . . . . .

General

AC Hipot

Voltage Range: 100 to 5000 VAC RMS
Voltage Setting Resolution: 5V/step
Voltage Regulation: 1% of reading + 5V
Voltage Accuracy: 1% of reading + 5V
Voltage Monitoring: At Output Terminals
Max Output Current: 20mA for 60s,
10mA continuous
Min/Max Current Limits: 0.01 to 20mA
Current Accuracy: 1% of reading + 0.05mA

DC Hipot

(V51, V53 only)

Voltage Range: 100 to 6000 VDC
Voltage Setting: Resolution: 5V/step
Voltage Regulation: 1% of reading + 5V
Voltage Accuracy: 1% of reading + 5V
Voltage Monitoring: At Output Terminals
Max Output Current: 7.5mA
Min/Max Current Limits: 0.01 to 7.5mA
Current Accuracy: 1% of reading + 0.05mA

Insulation Resistance

(V52, V53 only)

DC Output Voltage: 500V or 1000V
Resistance Range: 1 to 9999M

Resistance Accuracy: 1 to 500M

5% of

reading, 501 to 2000M

10% of reading

Continuity Measurement

Test Current: 100mA ± 10mA
Resistance Range: .001 to 1.500

Resistance Accuracy: 0.1

General

Test Database: 6 Test Sequences with up
to 6 steps per test sequence
Front Panel Lockout: Prevents database
edit while in lockout mode
Arc Detect: 10 level trip select
Remote Interface: 9-pin D-sub connector
with Outputs of Testing, Pass, Fail and
inputs of Start, Reset. Output isolation is
400V with 130mA Continuous load current.
Power Source: AC100V, 120V, 220V,
230V (±10% 50/60Hz), 250W max
Timer Accuracy: 0.05% ± 50mS
Operating Environment: Indoor use, Altitude
up to 6500ft (2000m). Installation Category
II. Pollution Degree 2
Operating Temperature: 0°C to 40°C, 80%
RH max.

W O R L D L E A D E R S I N C O M P L I A N C E A U T O M A T I O N

S M

Prices and specifications subject to change without notice. ©Copyright 2000
Vitrek Corporation, all rights reserved. Cindy/TY4TMW25YOML/Kevin