The FX100 is a cost effective paperless recorder with highly optimized performance.
Measured data can be easily viewed on the FX’s versatile displays, even in the field.
Unlike data from chart recorders, electrically stored data can be archived and copied
securely, quickly and easily without taking up space. The FX100 delivers what all
companies demand: reductions in TCO, improved efficiency, and enhanced control.
A Wide Variety of Highly Visible Displays
• 5.5’’ TFT color LCD display with wide viewing angle
• Trend, digital, bar, overview, information, and historical displays
• 4 display groups and 6 channels per group: Freely assignable measurement and
mathematical channels
• Display languages: English, German, French, or Japanese
Versatile Measurement
• Universal input and optional inputs (pulse and Pt1000 input)
• Up to 50 VDC direct input, no need of external voltage divider
• Up to 12 analog input channels
• Measurement interval: FX103: 250 ms
FX106, FX112: 1 s and 2 s
Simple and Easy Operation
• Interactive setup with Key panel’s navigation keys means easy operation
Dust-proof and Water-proof
(IP65)
• Can be installed in harsh environment
Easy Wiring
• Detachable analog input terminal makes it easy to wire
The Optimized Paperless Recorder in the Applications
Data Display that’s Easy-to-Read in the Field
Outstanding Display and Flexible Operation
Powerful and Useful Functions
Reliable Measurement
Secure Data Acquisition
PC Software
Meets Your Needs, Fits Your Applications
The FX100 provides an excellent alternative to chart recorders through enhanced data management and high performance. With a
powerful set of optional functions such as pulse input, Pt1000, and mathematical functions, the FX100 enables easy operation
tailored to your specific application, whether it be water treatment, wastewater treatment, heat treatment, process technology, or
environmental test equipment.
Data Display/Record in Wastewater Treatment
Temperature Recording/Monitoring for Aluminum Casting
Acquiring Sterilization Data for Food
Data Display/Record in Environmental Chamber
Remote Monitoring for Water Distribution
Powerful Computation Functions beyond Simple Calculation (/M1 Option)
• Multiple computations for measurement channels
• Displays and records12 mathematical channels
• Report function generates periodical report
Example
- When ch02 is high,
ch01 value is accumulated.
- When ch01 is over measurement higher limit,
total time is accumulated.
A Variety of Communication Option Combination (/C2, /C3, /C7 Option)
• The FX100 supports Ethernet, RS232, RS422A/RS485
• Communication interface can be used with the other options such as alarm output and fail/
memory end.
• Ethernet interface and RS232 or RS422A/RS485 can be used together
Alarm Level
ch01
ch02
Detachable clamp terminal
FX100 back side
Delivers Stable Measurement
• FX100 uses High-breakdown-voltage Solid-
state Relays as scanners for switching
signals, thus overcoming the problem of
defective measurement caused by faulty or
worn contacts of the mechanical contact.
• Resolution of A/D with 16 bits and isolated
channel inputs for DC voltage and TC input
make it stable measurement.
High-breakdown-voltage solid-state relays
Data security in binary format
Internal flash memory
Protects Data When Power Interrupted
• The internal flash memory is nonvolatile
(requiring no battery backup), and holds
measurement data even during a power
interruption.
Keeps Your Data Secure
• FX100 saves measurement data in binary
format which provides high level of security.
Standard software DAQSTANDARD
Online/Offline Configuration
• Setting can be sent to or received from the
FX100.
Data Viewer/Conversion
• Data can be displayed, printed, or converted
to ASCII, Lotus 1-2-3 and Excel format.
FX100 can display measured data and computation
results in real time.
■
Display and record Inputs data such as temperature, flow, turbidity,
pH, dissolved oxygen
■
Easy analysis data on the PC
■
Water quality management with the option Pt1000 (/N3):
Temperature display with high resolution
■
Pulse measurement up to 100Hz with option pulse input (/PM1):
Display/record of computations such as flow accumulation
Example
- Process flow (F1-F2) display/record.
The accumulation flow display on 31ch
Simplities casting temperature quality management.
■
Displays and records Aluminum casting data
- Molten metal temperature
- Cooling water temperature
■
Archives data upon alarm occurrence
- Analysis alarm data
Measurement:
Temperature/flow/turbidity
/pH/dissolved oxygen
Drawn flow(F1)
: ch01
Grit chamber
Effluent chamber
Effluent flow (F2)
: ch02
Records sterilization process with optional mathematical
function (/M1): Easy F0 computation
■
Multi points and mixed inputs types (Temperature, F0, pressure, etc)
record
■
Improve efficiency by electric record
■
Measurement ON/OFF by external input (option)
■
Storing files by each test
Analysis/Report
Easy data conversion to Excel format
Food sterilizer
FX100 measures accurate environmental test data and
displays data on versatile screen.
■
Records Data (temperature, humidity, voltage, current)
■
Versatile display enable easy interpretation of data
■
Easy data analyzing with PC software
■
Simple design and paperless recorder reduces TCO
Accurate measurement Versatile
displays
Simple data acquisition over a wide area networking is available with optional Ethernet communication port (/C7 option).
■
Effective data management/data monitoring
via wide area networking
■
Can select no external media (reduces TCO)
Stores data file in FTP server
■
Real time data monitoring at remote sites
■
E-mail notification upon occurrence of alarm
■
Generates periodic report (/M1 option)
Flow turbidity
Temp pH
Periodical data transfer (/M1)
EX. Per each a week
Telephone line
(ISDN, Analog)
water treatment A
water treatment B
Web Monitoring
Web Monitoring
Server
Web Monitoring
Data management
Office
Maintenance department
Printer for data form
LAN/WAN
Dial-up router
F0 computation
L
L
1
L
2
L
3
L
4
L
5
L
n
-2
L
n
-1
L
n
S
1
S
2
S
3
S
4
S
n
-2 S
n
-1
∆
t
∆
t
t
F0 is summation of area
L
1
S
1
S
2
S
3
S
4
S
n
-2 S
n
-1
L
2
L
3
L
4
L
5
L
n
-2
L
n
-1
L
n
Furnace data record
Molten metal temperature
Cooling water temperature
Melting furnace
Metal Mold