beautypg.com

Atec Tektronix-GB1400 User Manual

Page 2

background image

Specifications

Data Patterns

Format

NRZ-L, Normal and Complement

Type

PRBS or WORD (User-programmable)

PRBS Patterns

2

°

"'; n=7,15,17,20,23

WORD Lengths

8 and 16-bit only,

1 Mbit memory (with optional memory)

PRBS Phase Tap Information

The Pseudo-Random data patterns used in the GB 1400 TX are generated by shift-register and
exclusive-OR feedback technique. The pattern is dependent on which feedback taps (shift register
outputs) are selected.

For example, PN7 is defined as a seven-stage shift register, which the output of stages 6 and 7 fed
back (through an exclusive-OR gate) to the beginning of the shift register. The feedback taps used
in the GB 1400 are tabulated here.

Data Output (True and Complement)

Amplitude

Variable 0.5V to 2.OV, 50 mV steps

Baseline Offset

Variable -2.OV to +1.OV, 50 mV steps

-2.OV to +1.8V, 50 mV steps, with PECL option

Pulse Top Limit

+2.OV into 50 Ohms, +4.OV open load
+2.8V into 50 Ohms (with PECL option)

Rise/Fall Time

150 pS, typical (20-80%) at 1 V amplitude

Source Impedance

50 Ohms

Output Timing

CLOCK/DATA edge-aligned (+/- 100 pS)

Jitter:

100 pS, peak-to-peak Max. referenced to EXT clock

Connectors

SMA

Data Inhibit

Rear panel SMA, ECL (50 Ohms to -2V term)

Data Inhibit Rate

Asynchronous, 1 bit and 500 pS minimum width

Data Invert

Front Panel Selectable

A-2

GB1400 User Manual

Pattern

Feedback

Taps

PN7

6

7

PN15

14

15

PN17

14

17

PN20

17

20

PN23

18