beautypg.com

Ordering information, Specifications – Atec Rohde-Schwarz-FSE User Manual

Page 8

background image

18

Spectrum Analyzers FSE

Ordering information

Order designation

Type

Order No.

Spectrum Analyzer 9 kHz to 3.5 GHz

FSEA20

1065.6000.25

Spectrum Analyzer 20 Hz to 3.5 GHz

FSEA30

1065.6000.35

Spectrum Analyzer 9 kHz to 7 GHz

FSEB20

1066.3010.25

Spectrum Analyzer 20 Hz to 7 GHz

FSEB30

1066.3010.35

Spectrum Analyzer 9 kHz to 26.5 GHz

FSEM20

1080.1505.25

Spectrum Analyzer 20 Hz to 26.5 GHz

FSEM30

1079.8500.35

Spectrum Analyzer 9 kHz to 40 GHz

FSEK20

1088.1491.25

Spectrum Analyzer 20 Hz to 40 GHz

FSEK30

1088.3494.35

Accessories supplied
Power cable, operating manual, spare fuses;
FSEM: test-port adapter 3.5 mm female (1021.0512.00) and N female (1021.0535.00)
FSEK: test-port adapter K female (1036.4790.00) and N female (1036.4777.00)

Ordering information continued overleaf

FFT Filter FSE-B5

Analog filter

100 000

10 000

1000

100

10

1

0.1

0.01

1

3

10

100

300

30

Sweep time for 10 kHz Span

Sweep time (s)

RBW (Hz)

Specifications

FFT Filter FSE-B5

(standard in models 30)

• High frequency resolution due to very small

shape factor of 2.5

• Extremely short measurement time, up to 150

times faster than with conventional filters

Resolution bandwidths (RBW)
3 dB bandwidths,
in 1/2/3/5 steps

1 Hz to 1 kHz

Bandwidth error

2%, nom.

Shape factor 60:3 dB

2.5, nom.

Display range for frequency axis
Min. span

25 x RBW

Max. span

100 000 x RBW,
max. 2 MHz

Level measurement error
Additional total level error,
referred to RBW 5 kHz

<1 dB

Max. display range

100 dB

Immunity to interference
Spurious response

100 dBm

1 dB Attenuator FSE-B13

Frequency range

max. 7 GHz (stopp fre-
quency

7 GHz)

Setting range of
RF attenuation

0 dB to 70 dB

Step width

1 dB

Additional attenuator
uncertainty

<0.1 dB

External Mixing FSE-B21

LO output/IF input
(front panel)

SMA female , 50

LO signal

7.5 GHz to 15.2 GHz

Amplitude

+15.5 dBm ±3 dB

IF signal

741.4 MHz

Full-scale level

–20 dBm

IF input (front panel)

SMA female , 50

Frequency

741.4 MHz

Full-scale level

–20 dBm

Level measurement error
at IF inputs (IF level –30 dBm,
reference level –20 dBm,
RBW 30 kHz)

<1 dB

Increased Level Accuracy FSE-B22

Total level error

0.5 dB with 10 dB RF

attenuation

0,6 dB with 20/30/

40 dB RF attenuation

Specifications are valid for:
Temperature range

20 to 30

°

C

Frequency range

10 MHz to 2 GHz

Resolution bandwidths

5 to 30 kHz/300 kHz/
1 MHz

Signal level

10 dB to 50 dB below
reference level

Stop frequency

2 GHz

Sweep time

3 x auto sweep time

Broadband Output 741.4 MHz FSE-B23

FSE-B23 reduces the suppression of other interfer-
ence signals to

50 dBm and must not be combined

with FSE-K10/-K11.

FSEA FSEB FSEM

FSEK

Gain from RF
input to IF
output (dB)

6

6

4

4

3 dB BW
(MHz)

60 150

150

1

)

150

1

)

40 to 80

2

) 40 to 120

3

)

1

) f<7 GHz.

2

) 7 GHz to 26.5 GHz.

3

) 7 GHz to 40 GHz.