General

Integrating Sound Level Meter - Time weighting: Slow, Fast, Impulse, TWA, Peak (peak has independently
selectable frequency weighting) Frequency weighting: A, C, & Z, Octave, Fractional Octave (with OBA options).

Measurement
Range

LxT1

LxT2

LxT1L

with optional

LOW RANGE Pre-amp

LxT2L

with optional

LOW RANGE Pre-amp

A

38 to 140 dB SPL

37 to 140 dB SPL

27 to 118 dB SPL

29 to 121 dB SPL

C

37 to 140 dB SPL

37 to 140 dB SPL

29 to 118 dB SPL

32 to 121 dB SPL

Z

42 to 140 dB SPL

42 to 140 dB SPL

34 to 118 dB SPL

36 to 121 dB SPL

SPL maximum level

140 dB SPL

140 dB SPL

118 dB SPL

121 dB SPL

Peak level

143 dB

143 dB

121 dB

124 dB

Measurements (qty)

SPL, Leq, TWA (2), Lmin, Lmax, Lpeak, Lpeak (max), Dose (2), Proj. Dose (2), Lep,d, E, E8, E40, SEA, Ln (6), Event
Counters (3); (2 RMS, 3 Peak)

Data Storage / Communication

Flash Data Storage:

2GB standard

Communication

to PC via USB

Display / Keypad

Display: High contrast, monochrome, black on white, 1/8th VGA 160 x 240 dot graphics, 4 level grey-scale,
bright white LED backlighting

Keypad: Silicone elastomer “quiet touch” with tactile feedback, 4 dedicated function keys, 3 context soft-keys,
and 5 navigation keys

Power

Internal:

4 AA cells, 1.5 Volts each; Alkaline, NiMH, or Lithium

External:

5.0 VDC ±5%, 500mA maximum, USB powered

Battery life: Approximately 22 hours (alkaline cells), 30 Hours (lithium cells), depending on usage

Physical Characteristics

Dimensions: 8.8“ L x 2.8” W x 1.6” D (22.4 cm x 7.1 cm x 4.1 cm), 11.5” L (29.2 cm) with preamplifier

and microphone

Weight: 1.0 lbs (471 g), 1.1 lbs (513 g) with preamplifier and microphone

Environmental

Operating temperature: 14 to 122 °F (-10 to 50 °C)

Storage temperature: -22 to 140 °F (-30 to 60 °C)

Humidity: up to 95% non-condensing

International Protection Rating: IP 54

Standards Compliance

ANSI: S1.4-1985 (R 2001), S1.43-1997 (R 2002), S1.25-1991 (R 2007), S1.11-2004

IEC: 61672-2002, 60651-2001, 60804-2000, 61260-2001, 61252-2002

CE: Directive 2004/108/EC, IEC 61326-1:2005

Complementary Industrial Hygiene Products

Vibration Exposure
Monitors

3

Hand-Arm per ISO 5349,
ANSI S2.7

3

Whole-Body per ISO 2631

3

Complete with sensors
and easy to use

Noise Dosimeters

3

Compact

3

Rugged

3

100 Hour Battery Life

Options and Accessories

Firmware Options

LXT-LOG

Time History Data Logging

LXT-HSLOG

High Speed Logging Option (to 100ms)

LXT-ENV

Measurement History (intervals)

LXT-CN

Community Noise, Ldn & Lden

LXT-DVA

Digital Voice Annotation

LXT-OB1

1/1 Octave Real Time Filters

LXT-OB3

1/1 and 1/3 Octave Real Time Filters

Accessories

LXT-ACC

Type 1 Accessory Kit - Pelican case, CAL200 calibrator,
PC cable, AC adapter, windscreen and Utility Software

LXT-ACC1

Type 2 Accessory Kit - same as above
with CAL150 Type 2 calibrator

LXT-CCS

Hard Shell Pelican Carrying Case

CAL150

Type 2 Microphone Calibrator

CAL200

Type 1 Microphone Calibrator

SWW-DNA

Advanced Analysis Software

SWW-DNA-LXT

DNA Instrument Driver for Model LxT

SWW-BLAZE-LXT Industrial Hygiene Software for Model LxT

Special LxT Configurations

LXT1-QPR

High Decibel Configuration for Model LxT -
includes 1/4" microphone to measure >160dB

LXT1-NFR-PK1

Type 1 Noise N'Forcer Kit - includes portable printer

LXT2-NFR-PK2

Type 2 Noise N'Forcer Kit - includes portable printer

3425 Walden Avenue, Depew, NY 14043-2495 USA

Phone 716-926-8243

n

Toll-Free in USA 888-258-3222

n

Fax 716-926-8215

E-mail [email protected]

n

Web Site www.larsondavis.com

ISO 9001 CERTIFIED

© 2013 PCB Group, Inc. In the interest of constant product improvement, specifications are subject to change without notice. PCB, and ICP are regis-
tered trademarks of PCB Group Inc., SoundTrack LXT, Spark and Blaze are registered trademarks of PCB Piezotronics, Inc. HVManager is a trademark of
PCB Piezotronics, Inc. All other trademarks are property of their respective owners.

LD-SoundTrackLxT-0613

Printed in U.S.A

.

For environmental noise monitoring and building acoustics,

Larson

Davis

offers a full line of instruments, accessories and software.

For personal noise and vibration exposure monitoring, Larson Davis
complements this with sound level meters, personal noise
dosimeters, human vibration meters, audiometric calibration
systems and hearing conservation programs.

Visit

www.larsondavis.com to locate

your nearest sales office

Sound Level Meters for Safety & Health Professionals