Traditional single-axis shakers, Maximum ratings – Atec MB-Dynamics-PM250HP User Manual
Page 2
Traditional
Single-Axis Shakers
Maximum Ratings
C-SERIES
SHAKERS
M-SERIES AMPLIFIERS
FORCE RATINGS
Max
Accel
g's pk
SINE
Velocity
ips pk
SHOCK
Velocity
ips pk
30g
11ms
Payload
Cont.
Duty
Stroke
in pk-pk
Full
Perform.
Freq.
Range
Hz
ARMATURE
kVA Rating
Coupling
DC/Match
Configuration
MF=Max Force
MV=Max Velocity
SINE
1
lbs pk
RANDOM
2
lbs rms
SHOCK
lbs pk
Axial
Res.
Hz
Wt
lbs
Outer
Bolt Circle
inches
Diam.
inches
C150HP
96 kVA
96 kVA
48 kVA
48 kVA
DC
DC
DC
DC
MF
MV
MF
MV
20,000
16,000
14,300
9,200
18,000
13,500
12,900
8,200
36,000
27,000
24,000
18,400
150
150
145
93
45
70
46
70
45
90
46
92
1100
800
700
510
2
2-3 k
2,400
100
16
17.25
C90HP
48 kVA
48 kVA
42 kVA
24 kVA
DC
DC
DC
DC
MF
MV
MF
MF
10,000
7,600
10,000
7,600
8,500
6,400
8,500
6,400
17,000
12,800
17,000
12,800
150
150
150
150
54
70
54
54
54
108
54
54
520
380
520
380
2
2-3 k
2,550
39
12
13.25
C40HP
24 kVA
24 kVA
18 kVA
12 kVA
12 kVA
6 kVA
DC
DC
DC
DC
DC
DC
MF
MV
MF
MF
MV
MF
5,000
4,000
5,000
4,000
2,000
2,000
4,000
3,300
4,000
3,200
1,600
1,600
8,000
6,600
8,000
6,400
3,200
3,200
120
102
120
102
51
51
55
70
55
55
70
55
55
110
55
55
110
55
220
180
220
170
65
65
2
2-3 k
2,550
39
12
13.25
C10E
6 kVA
MATCH
MF
1,200
950
2,400
68
70
70
60
1
5-3 k
3,000
17.50
8.00
9.25
PM-SERIES
SHAKERS
SS-SERIES AMPLIFIERS
FORCE RATINGS
Max
Accel
g's pk
SINE
Velocity
ips pk
SHOCK
Velocity
ips pk
30 g
11 ms
payload
Max
Stroke
in pk-pk
Freq.
Range
Hz
ARMATURE
Model
Coupling
DC/Match
SINE
1
lbs pk
RANDOM
2
lbs rms
SHOCK
lbs pk
Res.
Hz
Weigh
t
lbs
Bolt Cricle
inches
Diam.
inches
PM500HP
SS2500
DC
500
*
250
*
500
80
55
55
10
2
DC-3 k
2,800
6.2
3.5
4.1
PM250HP
SS1200VCF
DC
250
*
125
*
250
80
55
55
5
2
DC-3.5 k
3,000
3.1
3.5
4.1
PM100A
SS530
DC
100
*
50
*
100
106
70
70
2
0.5
DC-7 k
6,000
0.94
2.25
2.7
PM50A
SS250
DC
50
*
25
*
50
80
70
70
1
0.5
DC-10 k
8,000
0.62
2.25
2.7
PM25A
SS250
DC
25
*
12
*
25
50
70
70
0.3
0.5
DC-10 k
8,000
0.5
2.25
2.7
Specifications subject to change without notice 11/95
*
Derate PM Sine force ratings by 50% if no forced air used
1
assumes 1 octave/min sweep rate in full-performance frequency range with pure mass payload equal to the armature weight
2