T-500 Series High Power TWT Microwave Power Amplifiers

1.0 – 18 GHz • 500 watts, Minimum Rated Power

Specifications subject to change without notice Page 2 ds-t500-series rev-
a-2/23/2011

Standard Features for IFI T-500 Series TWT Amplifiers

VSWR Reflected Power Protection, the unit operates without damage or oscillation into any magnitude of phase or load
impedance, Open & Short Circuit Protection.
* Alternate Prime Power

(specify at time of order)

GPIB IEEE 488 & RS232 Remote Control
RF Sample Port on the Front Panel,

112R for rear panel

Internal Pre-amplification to obtain rated output power with an input level of 0 dBm or less.
RF Input/Output Connectors on the Front Panel,

118R for rear panel

Internal Systems Diagnostics & Status Indicators
Filament/Beam Elapsed Time Metering in hours
RF Safety Interlock

Standard
Features

Forward/Reflected Power Indication simultaneously on Front Panel display

Specifications:

Frequency Range:

As Specified in Model Table

Rated Output Power:

As Specified in Model Table

Gain @ Rated Power:

As Specified in Model Table

Prime Power:

As Required for Customer (Some are listed below)

Input/output Impedance:

50 ohms

RF Input/ Sample Connectors: Type N Female, unless specified otherwise

RF Output Connector:

Type SC or 716 Female up to 8 GHz,
8-12 GHz is WR90, 12-18 GHz is WR62, 7.5-18 GHz is WRD750, 6.5-18 GHz is WRD650

Other waveguides available by request or specification (see Option 117)

Input VSWR:

2.0:1

Output VSWR:

2.5:1

Operating Temp:

0º to 50º C

Non-operating Temp/Altitude:

-40º to 70º C (50,000 feet max)

Humidity:

95% without condensation

Operating Altitude:

10,000 feet

Cooling System:

Air cooled, self-contained

Modulation:

All types, AM, FM, Pulse

Configuration:

Rack Mount as specified in Model Table, or Cabinet Integrated as needed

Spurious Outputs:

<-60 dBc nominal

Standard Prime Powers:

100, 115, 120 VAC ±10% 50/60 Hz, single phase
200, 220, 230, 240VAC ±10% 50/60 Hz, single phase
100/200VAC,115/208 or 200/220/230/240VAC ±10% 50/60 Hz, three phase Wye or Delta and/or 400 Hz power is available.

Special Prime Powers other then listed are subject to availability

Some Available Options for IFI T-500 Series TWT Amplifiers

Option 103 G/D:

VSWR Reflected Power Protection “Graceful Degradation Feature” which will automatically reduce the input drive
and fold back the output power when the average reflected power exceeds a preset limit of 3.0:1.
The unit operates without damage or oscillation into any magnitude of phase or load impedance.

Option 110-1E:

GPIB IEEE-488 RS232 and Ethernet Remote Control

Option 110-2:

GPIB IEEE-488 and RS 422 Remote Control

Option 110-3

GPIB IEEE-488 and RS 485 Remote Control

Option 113:

Chassis Slides for 19” Rack Mounting

Option 118F or R: Front Panel RF Connections 118R for Rear Panel RF Connections
Option 123F or R: Reflected RF Sample Port -40, -50 or -60dB N or SMA, Front or Rear Panel