Powerstar-110, Listed – Atec Simplex-PowerStar User Manual
Page 2

®
PowerStar-110
110 KW Digital Load Bank
with Network Capability • Page 2
Simplex, Inc.
5300 Rising Moon Road
Springfi eld, IL 62711-6228
217-483-1600
Fax 217-483-1616
www.simplexdirect.com
© 2013 Simplex, Inc. All Rights Reserved.
Printed in the USA • 1012-08.03
Design subject to change without notice.
Dimensions and Key
Features
1. Control Compartment Cooling
Fans (2)
2. Load Element Compartment
Cooling Fans (4)
3. Load Source Connections
4. Storage Compartment for
handheld controller
5. Handles (2)
6. RS-232 and 120V connectors
7. Swivel Casters (4)
Fan/Control Power
External, 115V, 1-ph., 60Hz, 15A
service, 15’ cord with plug provided
Voltage
Dual Voltage, nominal 240/480V AC,
3-phase
208-240/416-480V AC, 3-phase, 60Hz
190-220/380-460V AC, 3-phase, 50Hz
110-240V AC, 1-phase, 50-60Hz
Load Steps
Digital load control, 5kw resolution
Frequency
50–60Hz
Duty Cycle
Continuous
Temp Rating
125° F max intake air temp
Nominal 110° F rise
Weight
125 lbs.
Options
• Vinyl Cover
• Shipping / Storage Container
Model
FLA
KW DETAIL
240V
480V
240V/480V
208/416V
240V, 1-ph
PowerStar
264
132
110
82.5
73.3
Capacity Detail
LISTED
in Atlanta, GA.