Tip adaptor optical specifications – Atec Panametrics-Olympus-IPLEX-LT-LX User Manual
Page 15
![background image](/manuals/319333/15/background.png)
15
Tip Adaptor Optical Specifications
OPtICAl tIP ADAPtOR VARIAtION
6.0 mm Viewing tip Adaptors
At40D-IV86
At80D/
NF-IV86
At80D/
FF-IV86
At120D/
NF-IV86
At120D/
FF-IV86
At80s-IV86
At120s/
NF-IV86
At120s/
FF-IV86
Optical
system
Field of view
40º
80º
80º
120º
120º
80º
120º
120º
Direction of view
Forward
Forward
Forward
Forward
Forward
Side
Side
Side
Depth of field
3
200 to ∞ mm
8 to ∞ mm
35 to ∞ mm
4 to 190 mm
25 to ∞ mm
18 to ∞ mm
1 to 25 mm
5 to ∞ mm
Distal
end
Outer diameter
4
ø6.0 mm
ø6.0 mm
ø6.0 mm
ø6.0 mm
ø6.0 mm
ø6.0 mm
ø6.0 mm
ø6.0 mm
Distal end
5
19.8 mm
19.8 mm
19.8 mm
19.8 mm
19.8 mm
25.2 mm
25.2 mm
25.2 mm
MIl-stD COMPlIANCE
The operating environment performance is confirmed by the following MIL-STD-810G and MIL-STD-461F under battery operation.
type
Method
Vibration
1
MIL-STD-810F, Method 514.5, Procedure I (General vibration test)
Shock
MIL-STD-810G, Method 516.5, Procedure IV (Transit drop test)
Water Resistance
1
MIL-STD-810F, Method 506.4, Procedure I (Rain and Blowing rain test)
Humidity
1
MIL-STD-810F, Method 507.4
Salt Fog
1
MIL-STD-810F, Method 509.4
Sand and Dust
1
MIL-STD-810G, Method 510.4, Procedure I (Blowing dust test)
Icing/Freezing Rain
1
MIL-STD-810F, Method 521.2
Electromagnetic Interference (EMI)
2
MIL-STD-461F, RS-103, (Radiated susceptibility test for non-metallic above deck shipboard conditions)
Explosive Atmosphere
1
MIL-STD-810F, Method 511.4, Procedure I (Operation in an explosive atmosphere test)
1. Excluding IV88 series.
2. Excluding IV8675L1, IV8675L2, and IV88 series.
OPERAtING ENVIRONMENt
Operating Temperature
Insertion Tube
In air: –25 ºC to 100 ºC (–13 ºF to 212 ºF) IPLEX LX
–25 ºC to 80 ºC (–13 ºF to 176 ºF) IPLEX LT and IPLEX LX IV88 series
In water: 10 ºC to 30 ºC (50 ºF to 86 ºF)
Other parts than above
In air: –10 °C to 40 ºC (14 ºF to 104 ºF)
Operating Atmospheric Pressure
Insertion Tube
In air: 1013 hPa
In water: IV84 series — 1013 to 1368 hPa
IV86 series — 1013 to 1772 hPa
IV88 series — 1013 to 2026 hPa
Other parts than above
In air: 1013 hPa
Relative Humidity
All parts
15 % to 90 %
Liquid Resistance
All parts
Operable when exposed to machine oil, light oil or 5 % saline solution.
Waterproofing
Insertion Tube
Operable under water with viewing tip adaptor attached.
Not operable underwater with stereo measurement tip adaptors.
Other parts than above
Operable in blowing rain conditions (Battery compartment must be closed).
Not operable underwater.
3. Indicates the viewing distance with optimal focus.
4. The adaptor can be inserted into a ø4.0 mm, ø6.0 mm or ø8.5 mm hole when it is mounted on the scope.
5. Indicates the length of the rigid portion at the scope’s distal end when mounted.
4.0 mm Viewing tip Adaptors
8.5 mm Viewing tip Adaptors
6
At120D/
NF-IV84
At120D/
FF-IV84
At120s/
NF-IV84
At120s/
FF-IV84
At80D/
FF-IV88
At120D/
NF-IV88
At120D/
FF-IV88
At120s/
NF-IV88
At120s/
FF-IV88
Optical
system
Field of view
120º
120º
120º
120º
80º
120º
120º
120º
120º
Direction of view
Forward
Forward
Side
Side
Forward
Forward
Forward
Side
Side
Depth of field
3
4 to 190 mm 25 to ∞ mm 1 to 20 mm 6 to ∞ mm 35 to ∞ mm 4 to 190 mm 25 to ∞ mm 1 to 25 mm
5 to ∞ mm
Distal
end
Outer diameter
4
ø4.0 mm
ø4.0 mm
ø4.0 mm
ø4.0 mm
ø8.5mm
ø8.5mm
ø8.5 mm
ø8.5 mm
ø8.5 mm
Distal end
5
19.7 mm
19.6 mm
22.2 mm
22.2 mm
22.9 mm
22.9 mm
22.9 mm
29.5 mm
29.5 mm
stereo tip Adaptors (4.0 mm, 6.0 mm, and 8.5 mm)
At50D/50D-IV84
At50s/50s-IV84
At60D/60D-IV86
At60s/60s-IV86
At60D/60D-IV88
At60s/60s-IV88
Optical
system
Field of view
50º/50º
50º/50º
60º/60º
60º/60º
60º/60º
60º/60º
Direction of view
Forward/Forward
Side/Side
Forward/Forward
Side/Side
Forward/Forward
Side/Side
Depth of field
3
5 to ∞ mm
4 to ∞ mm
5 to ∞ mm
4 to ∞ mm
5 to ∞ mm
4 to ∞ mm
Distal
end
Outer diameter
4
ø4.0 mm
ø4.0 mm
ø6.0 mm
ø6.0 mm
ø8.5 mm
ø8.5 mm
Distal end
5
25.0 mm
28.8 mm
25.9 mm
32.2 mm
28.9 mm
36.5 mm