Base Instrument Package

DM4E Ultrasonic Thickness Gauge
Two 1.5V AA Alkaline Batteries
Carrying Case
Operating Instruction Card
Operating Manual
Certificate of Calibration

Accessories

RC-984
Rubber instrument case with prop-up stand,
adjustable neck and wrist straps, and hanging
loop
FB-579
Field Accessory Belt with removable pouches
LCC-326
Locking Transport and Storage Case
HTC-010
HiTempco Couplant (2 oz. tube)

Specifications

Operating Principle
Ultrasonic pulse/echo

DIALOG Intelligent Transducers -- automatically recognized for optimum performance. *2-pt. calibra-
tion required, auto probe zero inoperable. Note: Other standard probe models are available and
“special probes” are developed in our Application Lab to satisfy unique requirements.
• DM4E is covered by a full two year warranty on parts and labor

Krautkramer DM4E

Probe Zero Adjustment
Automatic, or manual 2-pt. calibration
V-Path Correction
Automatic, microprocessor controlled
Measuring Range
0.25"- 20.00" (.64-500mm) depending on probe,
material, surface condition, and temperature
Displayed Resolution
.001 or .01 up to 9.999 inches, .01 above
9.999 inches; .01 or .1 up to 99.99 mm,
.1 above 99.99 mm
Measurement Update Rate
4 Hz; 25 Hz in Minimum Capture Mode
Gain
Automatic
Material Velocity Range
39,000 to 393,700 in./sec.;
1000 to 9999 m/sec.
Receiver Bandwidth
1 MHz to 10 MHz (–3 dB)

Display Type
4 digit LCD, .5" (12.7 mm) high, direct drive,
with electroluminescent backlight
Power Supply
2 ea. 1.5V AA alkaline cells
Battery Life (operating time)
Up to 200 hours @25% duty cycle without
backlight
Auto Shutoff
After 3 minutes of non-use
Operating Temperature Range
+10°F to +120°F (-10°C to +50°C)
Size ( L x W x D)
5.8" x 3.0" x 1.4" (at thickest point);
146.0 mm x 76.2 mm 34.3 mm
Weight

9 oz. (255 g) including batteries
Hazardous Area Operation
Safe operation as defined by MIL-STD-810E,
method 511.3, procedure.

Application and Description

Model

Probe

Cable

Contact

Diameter

Frequency

Measuring Range

In Steel

Temperature

Range

High Sensitivity Fingertip

FH2E

Potted

380” (9.6 mm)

7.5

.030” - 2.0”
(.75 - 50 mm)

< 130° F
(< 538° C)

High Temperature

HT400

KBA533/536

.500” (12.7 mm)

5.0

.030"- 10.0"
(.76 - 254 mm)

<1 000° F
(< 538° C)

Thin Materials

DA312

KBA532

.300” (.76 mm)

10.0

.025"- 1.0"
(.64 - 25 mm)

< 130° F
(< 54° C)

High Penetration

DP 104

KBA532

1.25” (31.8 mm)

1.0

.200" (5 mm)
minimum

< 130° F
(< 54° C)

Penetration

DA 303

KBA533

.635” (16.2 mm)

2.0

.200" (5 mm)
minimum

< 140° F
(< 60° C)

General Purpose

DA 301

KBA533

.475” (12.1 mm)

4.0

.050"- 8.00"
(1.2 - 200 mm)

< 140° F
(< 60° C)

Wear Resistant

FH2E WR

Potted

.550” (14.0 mm)

7.5

.030"- 2.0"
(.75 - 50 mm)

< 130° F
(< 54° C)

High Sensitivity Fingertip

FH2E D

Potted

.380” (9.6 mm)

7.5

.030"- 2.0"
(.75 - 50 mm)

< 130° F
(< 54° C)

General Purpose

DM 401 GP

KBA533/
533A

.700” (17.8 mm)

5.0

.060"-8.0"
(1.5 –200mm)

< 300° F
(< 148° C)

General Purpose

DM 411 GP

DA 233

.700” (17.8 mm)

5.0

.060"-8.0"
(1.5 –200mm)

< 300° F
(< 148° C)

Small Dia. Fingertip

FH2E M

Potted

.280” (721 mm)

7.5

.0.030"-2.0"
(.75-50mm)

< 130° F
(< 54° C)

3 mm Footprint

DA 312B16*

Potted

.120” (3.0 mm)

10.0

.025"- .500"
(.6 - 13 mm)

< 130° F
(< 54° C)

GE Inspection Technologies

Ultrasonics