beautypg.com

New transducers – Atec Panametrics-Olympus-37DL-Plus User Manual

Page 2

background image

trAnsDUCers wIth AUtomAtIC probe reCoGnItIon AnD sInGLe eLement trAnsDUCers

PROBE

MHZ CABLE

CONN

TIP DIA

RANGE (steel)*

TEMP RANGE**

WAND

HOLDER (w/wand)

D790

Potted

Straight

.434”

0.040”-20”

-5° – 932°F

F152

F152A

D790-SM

5.0 LCMD-316-5B

Straight

(11.0 mm)

(1-500 mm)

(-20° – 500°C)

F152

F152A

D790-RL

LCLD-316-5G

Rt. Angle

D790-SL

LCLD-316-5H

Straight

D791

5.0 Potted

Rt. Angle .434”

0.040”-20”

-5° – 932°F

F153

(11.0 mm)

(1-500 mm)

(-20° – 500°C)

D791-RM

5.0 LCMD-316-5C Rt. Angle .434”

0.040”-20”

-5° – 752°F

(11.0 mm)

(1-500 mm)

(-20° – 400°C)

D792

10 Potted

Straight

.283”

0.020”-1”

32° – 122°F

F150

F150A

D793

Potted

Rt. Angle (7.2 mm)

(0.5-25 mm)

(0° – 50°C)

F151

D794

5.0 Potted

Straight

.283”

0.030”-2”

32° – 122°F

F150

F150A

D795

Potted

Rt. Angle (7.2 mm)

(0.75-50 mm)

(0° – 50°C)

F151

D797

2.0 Potted

Rt. Angle .900”

0.150”-25.00”

-5° – 752°F

D797-SM

LCMD-316-5D Straight

(22.9 mm)

(3.8-635 mm)

(-20° – 400°C)

D7226

7.5 Potted

Rt. Angle .350”

0.028”-4”

-5° – 300°F

D798-LF

(8.9 mm)

(0.71-100 mm)

(-20° – 150°C)

D798

7.5 Potted

Rt. Angle .283”

0.028”-4”

-5° – 300°F

D798-SM

LCMD-316-5J

Straight

(7.2 mm)

(0.71-100 mm)

(-20° – 150°C)

D799

5.0 Potted

Rt. Angle .434”

0.040”-20”

-5° – 300°F

(11.0 mm)

(1-500 mm)

(-20° – 150°C)

MTD705

5.0 LCLPD-78-5

Rt. Angle .200”

0.040”-0.75”

32° – 122°F

(5.1 mm)

(1.0-19 mm)

(0° – 50°C)

V260-SM

LCM-74-4

Straight

0.080”

0.020” –0.400”

32° – 122°F

Sonopen

®

V260-RM

LCM-74-4

Rt. Angle (2.0 mm)

(0.5-10 mm)

(0° – 50°C)

V260-45

LCM-74-x

45° Angle

D7906-SM

††

5.0 LCMD-316-5L Straight

.434”

0.040”-2.0”

32° – 122°F

F152

F152A

(11.0 mm)

(1-50 mm)

(0° – 50°C)

D7908

††

7.5 Potted

Rt. Angle .283”

0.028”-1.5”

(7.2 mm)

(0.71-37 mm)

M2017

20 LCM-74-4

Rt. Angle 0.25”

Steel 0.020”-0.500” 32° – 122°F

2127

(6.35 mm)

(0.5-12.0 mm)

(0° – 50° C)

Oxide 0.010”-0.050”

(0.25-1.25 mm)

M2091

20 LCM-74-4

Rt. Angle 0.25”

Steel 0.020”-0.500” 32° – 122°F

2127

(6.35 mm)

(0.5-12.0 mm)

(0° – 50° C)

Oxide 0.006”-0.050”

(0.15-1.25 mm)

E110-SB

LCB-74-4 and

Straight

1.25”

0.080”-5.00”

32° – 176°F

1/2XA/E110

(28.5 mm)

(2.0-125 mm)

(0° – 80°C)

* Dependent on material, transducer type, surface condition, and temperature

† Stainless steel cable available; consult us for part numbers

** Maximum temperature is with intermittent contact only

†† Transducers used for Thru-Coat technology

new trAnsDUCers

The 37DL PLUS can be used with a vast array of dual element and
single element transducers. Its full line of D790 series dual element
transducers feature Automatic Probe Recognition to provide maximum
gage performance for each transducer. The 37DL PLUS also has the ability
to use the E110-SB EMAT transducer for no-couplant steel thickness
measurements through oxide-scaled surfaces. The M2017 and M2091
transducers are ideally suited for measuring internal oxide/scale build-up
on boiler tubes. The 37DL PLUS is also compatible with the Panametrics-
NDT complete line of Microscan single element direct contact, delay line,
and immersion transducers ranging in frequency from 2 to 30 MHz. As
a result, the gage can be used for non-corrosion applications involving
materials such as plastic, fiberglass, composites, rubber, castings, rubber
and glass. Application Auto-Recall automatically recalls 16 default and 10
custom Microscan transducer setups from the gage’s memory.